SKC Inc. The World Leader in Sampling Technologies
English
Espanol
Deutsch
Francais
Portugues
systransoft.com
  Headlines:
          New! SKC Webinars/Podcast
    
Deal of the Month.  Special pricing Click Here

Grab Sample Tubes for
Piston Pump

GASTEC GV100 Piston Pump cat. no. 810-GV100

Gastec® GV110 Piston Style Detector Tube Pump

Download Gastec Price List (PDF)

Chemical hazard CAS No. Measuring Range
(ppm)
No.
of Test
Cat. No.
Acetaldehyde
Tubes to be stored at 40 F (5 C) or below
75-07-0 5 - 750 10 810-92
Acetaldehyde
Tubes to be stored at 40 F (5 C) or below
75-07-0 1 - 20 10 810-92L
Acetaldehyde
Tubes to be stored at 40 F (5 C) or below
75-07-0 2.5 - 100 10 810-92M
Acetic acid 64-19-7 1 - 100 10 810-81
Acetic acid
(SEI) Safety Equipment Institute Certified Tube
64-19-7 0.125 - 25 10 810-81L
Acetone 67-64-1 0.05 - 2% V 10 810-151
Acetone
Tubes to be stored at 40 F (5 C) or below
(SEI) Safety Equipment Institute Certified Tube
67-64-1 50 - 12,000 10 810-151L
Acetylene 74-86-2 0.05 - 4% V 10 810-171
Acid gases (acetic acid) 64-19-7 1 - 80 10 810-80
Acrolein
Tubes to be stored at 40 F (5 C) or below
107-02-8 3.3 - 800 10 810-93
Acrylonitrile
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
107-13-1 2 - 360 5 810-191
Acrylonitrile
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
107-13-1 0.1 - 18 5 810-191L
Amines   1 - 280 10 810-180
Amines   0.25 - 39 10 810-180L
Ammonia 7664-41-7 0.2 - 32% V 10 810-3H
Ammonia 7664-41-7 0.05 - 3.52% V 10 810-3HM
Ammonia 7664-41-7 0.5 - 78 10 810-3L
Ammonia
(SEI) Safety Equipment Institute Certified Tube
7664-41-7 2.5 - 200 10 810-3LA
Ammonia 7664-41-7 10 - 1000 10 810-3M
n-Amyl acetate 628-63-7 10 - 200 10 810-147
Aniline 62-53-3 1.25 - 60 10 810-181
Aromatic hydrocarbons   2 - 100 10 810-120
Arsine 7784-42-1 0.04 - 10 10 810-19LA
Benzene
(SEI) Safety Equipment Institute Certified Tube
71-43-2 2.5 - 120 10 810-121
Benzene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-43-2 0.1 - 65 5 810-121L
Benzene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-43-2 2 - 312 5 810-121S
Benzene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-43-2 1 - 100 5 810-121SL
Benzene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-43-2 0.2 - 66 5 810-121SP
Butadiene 106-99-0 50 - 800 10 810-174
Butadiene 106-99-0 2.5 - 100 10 810-174L
Butadiene
Tubes to be stored at 40 F (5 C) or below
106-99-0 0.5 - 5 5 810-174LL
n-Butane 106-97-8 25 - 1400 10 810-104
n-Butanol 71-36-3 10 - 150 10 810-114
2-Butanol 78-92-2 5 - 150 10 810-115
sec-Butanol 78-92-2 5 - 150 10 810-115
Butyl acetate 123-86-4 0.05 - 0.8% V 10 810-142
Butyl acetate 123-86-4 10 - 300 10 810-142L
n-Butyl alcohol 71-36-3 10 - 150 10 810-114
sec-Butyl alcohol 78-92-2 5 - 150 10 810-115
tert-Butyl mercaptan 75-66-1 2.5 - 150 mg/m3 10 810-75
tert-Butyl mercaptan
Tubes to be stored at 40 F (5 C) or below
75-66-1 0.5 - 30 mg/m3 10 810-75L
tert-Butyl mercaptan + Dimethyl sulfide
Separate quantification tubes: two different tubes supplied to detect two different hazards
Tubes to be stored at 40 F (5 C) or below
75-66-1 , 75-18-3 1 - 15 mg/m3 5 810-77
Carbon dioxide 124-38-9 0.5 - 20% V 10 810-2H
Carbon dioxide 124-38-9 2.5 - 40% V 10 810-2HH
Carbon dioxide
Injection type detector tube
124-38-9 10 - 100% V 10 810-2HT
Carbon dioxide
(SEI) Safety Equipment Institute Certified Tube
124-38-9 0.13 - 6% V 10 810-2L
Carbon dioxide 124-38-9 100 - 4000 10 810-2LC
Carbon dioxide 124-38-9 300 - 5000 10 810-2LL
Carbon disulfide
(SEI) Safety Equipment Institute Certified Tube
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-15-0 0.63 - 100 5 810-13
Carbon disulfide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-15-0 0.1 - 8.1 5 810-13L
Carbon disulfide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-15-0 20 - 4000 5 810-13M
Carbon monoxide 630-08-0 0.1 - 10% V 10 810-1H
Carbon monoxide 630-08-0 1 - 50% V 10 810-1HH
Carbon monoxide 630-08-0 2.5 - 2000 10 810-1L
Carbon monoxide
(SEI) Safety Equipment Institute Certified Tube
630-08-0 8 - 1000 10 810-1LA
Carbon monoxide 630-08-0 1 - 30 10 810-1LC
Carbon monoxide 630-08-0 5 - 600 10 810-1LK
Carbon monoxide (in hydrogen with hydrocarbons)
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
630-08-0 5 - 100 5 810-1LKC
Carbon monoxide 630-08-0 5 - 50 10 810-1LL
Carbon monoxide 630-08-0 25 - 2000 10 810-1LM
Carbon monoxide 630-08-0 0.05 - 4% V 10 810-1M
Carbon tetrachloride
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
56-23-5 0.5 - 60 5 810-134
Carbon tetrachloride
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
56-23-5 0.25 - 12 5 810-134L
Carbonyl sulfide
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
463-58-1 5 - 200 5 810-21
Carbonyl sulfide
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
463-58-1 2 - 125 5 810-21LA
Chloride ion in solution 16887-00-6 25 - 1000 mg/L 10 810-221L
Chloride ion in solution 16887-00-6 10 - 200 mg/L 10 810-221LL
Chlorine 7782-50-5 25 - 1000 10 810-8H
Chlorine 7782-50-5 0.25 - 10% V 10 810-8HH
Chlorine
(SEI) Safety Equipment Institute Certified Tube
7782-50-5 0.1 - 16 10 810-8LA
Chlorine
Tubes to be stored at 40 F (5 C) or below
7782-50-5 0.025 - 2 10 810-8LL
Chlorine dioxide 10049-04-4 0.025 - 1.2 10 810-23L
Chlorine dioxide 10049-04-4 01. - 10 10 810-23M
Chlorobenzene 108-90-7 2 - 500 10 810-126
Chlorobenzene
Tubes to be stored at 40 F (5 C) or below
108-90-7 0.5 - 43 10 810-126L
Chlorofluorocarbons   1 - 54 10 810-51L
Chlorofluorocarbons
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
(Pyrotec Pyrolyzer required)
  10 - 400 5 810-51
Chlorofluorocarbons
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
(Pyrotec Pyrolyzer required)
  250 - 6000 5 810-51H
Chloroform
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
67-66-3 4 - 400 5 810-137
Chloroform
Tubes to be stored at 50 F (10 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
67-66-3 0.5 - 30 5 810-137LA
Chloroform
Tubes to be stored at 50 F (10 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
67-66-3 0.3 - 4.5 5 810-137LL
Cresol
Tubes to be stored at 40 F (5 C) or below
1319-77-3 0.4 - 62.5 10 810-61
Cyclohexanol 108-93-0 5 - 100 10 810-118
Cyclohexanone
Tubes to be stored at 40 F (5 C) or below
108-94-1 2 - 75 10 810-154
Diborane 19287-45-7 0.02 - 5 10 810-22
Dichlorobenzene 25321-22-6 2.5 - 300 10 810-127
1,2-Dichloroethylene
Tubes to be stored at 40 F (5 C) or below
540-69-0 5 - 250 10 810-139
Dimethyl acetamide 127-19-5 1.5 - 240 10 810-184
Dimethyl formamide 68-12-2 0.8 - 90 10 810-183
Dimethyl sulfide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
(Pyrotec Pyrolyzer required)
75-18-3 0.25 - 10 10 810-53
Ethanol 64-17-5 0.01 - 7.5% V 10 810-112
Ethanol 64-17-5 50 - 2000 10 810-112L
Ethyl acetate 141-78-6 0.1 - 1.5% V 10 810-141
Ethyl acetate 141-78-6 25 - 800 10 810-141L
Ethyl alcohol 64-17-5 0.01 - 7.5% V 10 810-112
Ethyl alcohol 64-17-5 50 - 2000 10 810-112L
Ethylene 74-85-1 25 - 800 10 810-172
Ethylene 74-85-1 0.2 - 50 10 810-172L
Ethylene glycol
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
107-21-1 10 - 100 mg/m3 5 810-165L
Ethylene oxide 75-21-8 0.05 - 3% V 10 810-163
Ethylene oxide
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-21-8 0.4 - 350 5 810-163L
Ethyl ether 60-29-7 0.04 - 1% V 10 810-161
Ethyl ether 60-29-7 10 - 1200 10 810-161L
Ethyl mercaptan 75-08-1 0.5 - 120 10 810-72
Ethyl mercaptan 75-08-1 0.2 - 75 10 810-72L
Ethyl mercaptan 75-08-1 2.5 - 40 10 810-72P
Formaldehyde
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
50-00-0 2 - 100 5 810-91
Formaldehyde
Tubes to be stored at 40 F (5 C) or below
50-00-0 0.1 - 40 10 810-91L
Formaldehyde 50-00-0 0.05 - 1 10 810-91LL
Formaldehyde
Tubes to be stored at 40 F (5 C) or below
50-00-0 8 - 6400 10 810-91M
Gasoline 8006-61-9 0.015 - 1.2% V 10 810-101
Gasoline 8006-61-9 30 - 2000 10 810-101L
n-Hexane 110-54-3 0.015 - 1.2% V 10 810-102H
n-Hexane 110-54-3 10 - 1200 10 810-102L
Hydrazine 302-01-2 0.05 - 2 10 810-185
Hydrocarbons   0.05 - 2.4% V 9 810-103
Hydrocarbons   100 - 3000 10 810-105
Hydrocarbons, petroleum distillate   0.5 - 28 mg/L 10 810-106
Hydrogen 133-74-0 0.5 - 2% V 10 810-30
Hydrogen chloride
(SEI) Safety Equipment Institute Certified Tube
7647-01-0 0.2 - 76 10 810-14L
Hydrogen chloride 7647-01-0 10 - 1000 10 810-14M
Hydrogen chloride 7647-01-0 50 - 5000 10 810-14R
Hydrogen cyanide 74-90-8 0.05 - 1.6% V 10 810-12H
Hydrogen cyanide
(SEI) Safety Equipment Institute Certified Tube
74-90-8 0.36 - 120 10 810-12L
Hydrogen cyanide 74-90-8 0.2 - 7 10 810-12LL
Hydrogen cyanide 74-90-8 17 - 2400 10 810-12M
Hydrogen fluoride 7664-39-3 0.25 - 100 10 810-17
Hydrogen fluoride 7664-39-3 0.09 to 72 10 810-17L
Hydrogen fluoride 7664-39-3 0.05 to 24 10 810-17LL
Hydrogen peroxide 7722-84-1 0.5 - 10 10 810-32
Hydrogen sulfide 7783-06-4 10 - 4000 10 810-4H
Hydrogen sulfide 7783-06-4 0.1 - 4% V 10 810-4HH
Hydrogen sulfide 7783-06-4 25 - 1600 10 810-4HM
Hydrogen sulfide 7783-06-4 0.25 - 20% V 10 810-4HP
Hydrogen sulfide 7783-06-4 1 - 40% V 10 810-4HT
Hydrogen sulfide 7783-06-4 1 - 240 10 810-4L
Hydrogen sulfide 7783-06-4 0.5 - 12 10 810-4LB
Hydrogen sulfide 7783-06-4 1 - 40 10 810-4LK
Hydrogen sulfide
(SEI) Safety Equipment Institute Certified Tube
7783-06-4 0.25 - 120 10 810-4LL
Hydrogen sulfide
Tubes to be stored at 40 F (5 C) or below
7783-06-4 0.1 - 4 10 810-4LT
Hydrogen sulfide 7783-06-4 12.5 - 500 10 810-4M
Hydrogen sulfide + sulfur dioxide (simultaneous)
Separate quantification tubes: two different tubes supplied to detect two different hazards
7783-06-4, 7446-09-5 1.25 - 120 H2S 5 810-45S
Hydrogen sulfide + sulfur dioxide (total) 7783-06-4, 7446-09-5 0.02 - 8% V 10 810-45H
Isoamyl acetate 123-92-2 10 - 200 10 810-148
Isoamyl alcohol 123-51-3 5 - 300 10 810-117
Isobutyl acetate 110-19-0 10-300 10 810-144
Isobutyl alcohol 78-83-1 10 -150 10 810-116
Isopropyl acetate 108-21-4 20-500 10 810-146
Isopropyl alcohol 67-63-0 0.02 - 5.0% V 10 810-113
Isopropyl alcohol 67-63-0 25 - 800 10 810-113L
Isopropyl alcohol 67-63-0 20 to 440 10 810-113LL
LP gas 68476-85-7 0.02 - 0.8% V 10 810-100A
Mercaptans   0.5 - 120 10 810-70
Mercaptans   0.1 - 8 10 810-70L
Mercury vapor 7439-97-6 0.05 - 13.2 mg/m3 10 810-40
Methacrylonitrile
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
126-98-7 0.2 - 32 5 810-192
Methanol 67-56-1 0.002 - 4.5% V 10 810-111
Methanol 67-56-1 20 - 1000 10 810-111L
Methanol 67-56-1 2 - 56 10 810-111LL
Methyl alcohol 67-56-1 0.002 - 4.5% V 10 810-111
Methyl alcohol 67-56-1 20 - 1000 10 810-111L
Methyl alcohol 67-56-1 2 - 56 10 810-111LL
Methyl bromide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
74-83-9 10 - 600 5 810-136H
Methyl bromide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
74-83-9 2.5 - 200 5 810-136L
Methyl bromide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
74-83-9 1 - 36 5 810-136LA
Methyl bromide
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
74-83-9 0.1 - 3 5 810-136LL
Methyl chloroform (Trichloroethane)
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-55-6 100 - 2000 5 810-135
Methyl chloroform (Trichloroethane)
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-55-6 6 - 900 5 810-135L
Methyl cyclohexanone
Tubes to be stored at 40 F (5 C) or below
583-60-8 2 -100 10 810-155
Methyl cyclohexonal 25639-42-3 5 - 100 10 810-119
Methylene chloride
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-09-2 25 - 500 5 810-138
Methylene chloride
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-09-2 4 - 150 5 810-138L
Methyl ethyl ketone 78-93-3 0.02 - 0.6% V 10 810-152
Methyl ethyl ketone 78-93-3 10 - 384 ppm 5 810-152L
Methyl isobutyl ketone 108-10-1 0.01 - 0.6% V 10 810-153
Methyl isobutyl ketone 108-10-1 2.5 - 130 ppm 5 810-153L
Methyl mercaptan 74-93-1 0.25 - 140 10 810-71
Methyl mercaptan 74-93-1 20 - 2700 10 810-71H
Methyl methacrylate 80-62-6 10 - 500 10 810-149
Monochlorobenzene 108-90-7 2 - 500 10 810-126
Monochlorobenzene 108-90-7 0.5 - 43 10 810-126L
Naptha petroleum 8032-32-4 0.5 - 28 mg/L 10 810-106
Nitric acid 7697-37-2 0.1 - 40 10 810-15L
Nitro compounds
(Pyrotec Pyrolyzer required)
  0.5 - 30 10 810-52
Nitrogen dioxide
(SEI) Safety Equipment Institute Certified Tube
10102-44-0 0.5 - 125 10 810-9L
Nitrogen oxides
(SEI) Safety Equipment Institute Certified Tube
Separate quantification tubes: two different tubes supplied to detect two different hazards
  2.5 - 200 5 810-10
Nitrogen oxides   50 - 2500 10 810-11HA
Nitrogen oxides   0.04 - 16.5 10 810-11L
Nitrogen oxides   5 - 625 10 810-11S
Nitroparaffins
(Pyrotec Pyrolyzer required)
  0.5 - 30 10 810-52
Nitrous acid   10 - 100 10 810-11S
Oxygen
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
7782-44-7 3 - 24% V 5 810-31B
Ozone
(SEI) Safety Equipment Institute Certified Tube
10028-15-6 0.025 - 3 10 810-18L
Ozone
(SEI) Safety Equipment Institute Certified Tube
10028-15-6 4 - 400 10 810-18M
2-Pentenenitrile
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
13284-42-9 0.5 - 15 5 810-193
Petroleum naptha 8032-32-4 0.5 - 28 mg/L 10 810-106
Phenol
Tubes to be stored at 40 F (5 C) or below
108-95-2 0.4 - 187 10 810-60
Phosgene
Tubes to be stored at 40 F (5 C) or below
77-44-5 0.05 - 20 10 810-16
Phosphine 7803-51-2 2.5 - 100 10 810-7
Phosphine 7803-51-2 200 to 5500 10 810-7H
Phosphine 7803-51-2 2.5 - 1000 10 810-7J
Phosphine 7803-51-2 0.15 - 5 10 810-7L
Phosphine
(SEI) Safety Equipment Institute Certified Tube
7803-51-2 0.05 - 9.8 10 810-7LA
Polytec I
(Pyrotec Pyrolyzer required)
  Qualitative 10 810-107
Polytec II
(Pyrotec Pyrolyzer required)
  Qualitative 10 810-25
Polytec III
(Pyrotec Pyrolyzer required)
  Qualitative 10 810-26
Polytec IV
(Pyrotec Pyrolyzer required)
  Qualitative 10 810-27
Propane
Injection type detector tube
  0.1 - 2% V 10 810-100B
Propyl acetate 109-60-4 20 - 500 10 810-145
Pyridine 110-86-1 0.2 - 35 10 810-182
Stoddard solvent 8052-41-3 50 - 8000 mg/m3 10 810-128
Styrene 100-42-5 10 - 1500 10 810-124
Styrene 100-42-5 2 - 100 10 810-124L
Sulfide ion   0.5 - 20 10 810-211LL
Sulfide ion   2 - 300 10 810-211M
Sulfur dioxide 7446-09-5 0.5 - 8.0% V 10 810-5H
Sulfur dioxide 7446-09-5 1.25 - 200 10 810-5L
Sulfur dioxide 7446-09-5 0.5 - 60 10 810-5LA
Sulfur dioxide
(SEI) Safety Equipment Institute Certified Tube
7446-09-5 0.05 - 10 10 810-5LB
Sulfur dioxide 7446-09-5 20 - 3600 10 810-5M
Sulfur dioxide in CO2 7446-09-5 , 124-38-9 0.1 - 25 10 810-5LC
Sulfuric acid 7664-93-9 1 - 5 mg/m3 10 810-35
Tetrachloroethylene
Tubes to be stored at 40 F (5 C) or below
127-18-4 7 - 900 10 810-133HA
Tetrachloroethylene
Tubes to be stored at 40 F (5 C) or below
127-18-4 1 - 75 10 810-133L
Tetrachloroethylene
Tubes to be stored at 40 F (5 C) or below
127-18-4 0.1 - 9 10 810-133LL
Tetrachloroethylene
Tubes to be stored at 40 F (5 C) or below
127-18-4 2 - 250 10 810-133M
Tetrahydrofuran 109-99-9 20 - 800 10 810-159
Tetrahydrothiophene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
110-01-0 1 - 10 5 810-76
Tetrahydrothiophene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
110-01-0 10 - 200 5 810-76H
Tetrahydrothiophene
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
110-01-0 10 - 100 mg/m3 5 810-76M
Toluene
(SEI) Safety Equipment Institute Certified Tube
108-88-3 5 - 690 10 810-122
Toluene 108-88-3 1 - 100 10 810-122L
Total mercaptans   0.5 - 120 10 810-70
Total mercaptans   0.1 - 8 10 810-70L
1,1,1,-Trichloroethane (Methyl chloroform)
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-55-6 100 - 2000 5 810-135
1,1,1,-Trichloroethane (Methyl chloroform)
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
71-55-6 6 - 900 5 810-135L
Trichloroethylene 79-01-6 20 - 1300 10 810-132HA
Trichloroethylene 79-01-6 0.05 - 2.5% V 10 810-132HH
Trichloroethylene 79-01-6 1 - 70 10 810-132L
Trichloroethylene 79-01-6 0.125 - 8.8 10 810-132LL
Trichloroethylene 79-01-6 2 - 250 10 810-132M
Vinyl acetate
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
108-05-4 5 - 250 5 810-143
Vinyl chloride 75-01-4 0.025 - 2% V 10 810-131
Vinyl chloride
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-01-4 0.1 - 6.6 5 810-131L
Vinyl chloride
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-01-4 0.25 - 54 5 810-131LA
Vinyl chloride 75-01-4 0.25 - 70 10 810-131LB
Vinylidene chloride
Tubes to be stored at 40 F (5 C) or below
Twin tubes: first tube is a scrubber/oxidizer tube, the second tube provides the reading
75-35-4 0.4 - 40.6 5 810-130L
Water vapor 7732-18-5 0.5 - 32 mg/L 10 810-6
Water vapor 7732-18-5 0.05 - 2 mg/L 10 810-6L
Water vapor 7732-18-5 2 - 10 lb/MMCF 10 810-6LLP
Water vapor pipeline dew point   3 - 100 lb/MMCF 10 810-6LP
Xylene 1330-20-7 5 - 625 10 810-123
Xylene 1330-20-7 2 - 200 10 810-123L

 

Caution: Interchanging brands of pumps and tubes may produce a significant reduction in accuracy and is not recommended.

 

Chemical Hazard Search:
CAS No. Search: 

 

 


This page was last modified January 25, 2010
  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified May 16, 2012
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2012 SKC Inc