SKC Deployable Sampler Systems
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
![]() |
Originally designed for the U.S. Military, SKC now offers portable, lightweight, and cost-effective ambient air sampling systems. Two complete sampling systems are available: one is designated for particulates PM10 or PM2.5, the other is for polycyclic aromatic hydrocarbons (PAHs)/polyhalogenated dibenzo-p-dioxins (PHDDs)/polyhalogenated dibenzofurans (PHDFs). Both kits feature the fully programmable Leland Legacy Sample Pump with high-power Li-Ion battery for over 24 hours of run time. Specially designed sampling heads are easily loaded with media and deployed. Accessories such as a quick-mount bracket and quick-connect tubing provide for convenient setup. Unlike other ambient sampling systems, SKC deployable systems fit into one heavy-duty, compact Pelican case that is easily carried or shipped and takes only a few minutes to deploy. The pump operates from inside the case for protection during sampling. SKC deployable sampler systems offer the added advantage of PC programmability with the DataTrac Software accessory for advanced scheduling options and record keeping.
Deployable Systems Performance Profile| Flow Rate | 10 L/min |
| Run Time | > 24 hrs (one battery charge) |
| Power | Rechargeable Li-Ion battery, 7.4 V, 12-Ah capacity, 88.8 Wh |
| Case Dimensions | 18.5 x 14.1 x 6.9 in (47 x 36 x 18 cm) |
| System Weight |
DPS: 13 lbs (5.9 kg)
DCS: 12.2 lbs (5.5 kg) |

Patented IMPACT sampling head for DPS
For more information, see the Impact
Sampler page.
U.S. Patent No. 7,334,453
| Description | Qty. | ||
DPS System includes
a Leland Legacy sample pump with connection case, and charger
(100-240 V), 2 external battery assemblies with adapters (packaged
separately), IMPACT* sampling
head, 2 filter cassettes, calibration adapter, rain
cover for sampling head, 25 disposable impaction disks (limited
shelf-life), filter cassette opener, tubing
with
quick-connect fitting, calibration tubing and mounting bracket
in a heavy-duty lockable carry case. |
PM10 Kit |
ea | |
| ea | |||
| Collection
Filters for DPS System (not supplied with system) Select a collection filter based on your application; required for sampling |
|||
| Quartz Filters, 47 mm, Tissuquartz, 432 µm thick | 25 | ||
| PTFE Filters, 47
mm, 2.0-µm pore size, with PMP support ring Back pressure on PTFE filters can vary within the same lot. The maximum operating temperature is 464 F (240 C) based on PMP support ring. |
50 | ||
| Accessories | |||
| Replacement Impaction Disks, 37 mm, pre-oiled, ready to use, disposable, required for sampling, limited shelf-life | 25
|
||
50
|
|||
| Replacement Filter Cassette | ea | ||
| Replacement Calibration Tubing for DPS/DCS, Tygon®, 5/16-inch ID, 9/16-inch OD, 1-foot length | ea | P3006 | |
| Calibration Tubing for DPS/DCS, Tygon, 5/16-inch ID, 9/16-inch OD, 10 feet | ea | ||
| Petri Dish Slide, for filter transport | 100 | ||
DataTrac Software for Leland Legacy includes software on CD, DataTrac adapter, and DataTrac cable Requires Windows 98 or higher and available serial port or USB to serial adapter compatible with PC and system |
ea | ||
| Calibration Adapter, for IMPACT Sampler | ea
|
||
DPS
Spec. Sheet (PDF)
DPS
Operating Instructions (PDF)
DPS Quick
Guide (PDF)
Deployable
Particulate Sampler (DPS) Poster Presentation at NAVY’s 45th
Annual Occupational Health and Preventative Medicine Conference
(PDF)
Modular
Impactors Poster Presentation (PDF)
SKC Deployable Sampler
Systems Video (WMV)

| Description | Cat. No. |
| DCS System includes sample pump
with connection case, charger (100-240 V),
2 external
battery assemblies, sampling
head, calibration adapter, rain cover for sampling head, sample
tubing with quick-connect fitting, calibration tubing, and mounting
bracket
in a heavy-duty
lockable carry case. Two external battery assemblies with adapters
are packaged separately. Cartridges, filters, and media available separately |
|
| Media, required,/select based on application | |
| Cartridge for TO-9A includes PUF/quartz filter in a glass cartridge | |
| Cartridge for TO-13A includes XAD®-2 sorbent/quartz filter in a glass cartridge | |
| Accessories | |
DataTrac Software for Leland Legacy includes software on CD, DataTrac adapter, and DataTrac cable Requires Windows 98 or higher and available serial port or or USB to serial adapter compatible with PC and system |
|
| Replacement Calibration Tubing for DPS/DCS, Tygon®, 5/16-inch ID, 9/16-inch OD, 1-foot length | P3006 |
| Calibration Tubing for DPS/DCS, Tygon, 5/16-inch ID, 9/16-inch OD, 10 feet | |
Reference
Patterson, S. L., Rusiecki, J. A., Barnes, S. L., Heller, J. M., Sutphin, J.
B., Kluchinsky Jr., T. A., “Effectiveness, Suitability, and Performance Testing
of the SKC Deployable Particulate Sampler (DPS) as Compared to the Currently
Deployed Airmetrics MiniVol Portable Air Sampler,” Journal
of Environmental Health, Vol. 73, No. 3, pp. 16 to 22
DCS Operating Instructions (PDF)
SKC Deployable Sampler Systems Video (WMV)
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |