SKC: Shaping the Future of Air Sampling  

 

 

EVM-7 Environmental Monitor

2 Instruments in 1 for Particulate and Gas Measurement
EVM-7 Environmental Monitor 755-EVM7

EVM Monitor Spec. Sheet (PDF)

EVM-7 Key Features:
  • Simultaneously measures particulate and gas concentrations
    • Reduces the need for multiple instruments
    • Also measures VOCs (PID), toxic gas, carbon dioxide, relative humidity, temperature, and air velocity (with Air Probe-10 accessory)

  • Dial-in rotary impactor
    • Twist and click selection of PM2.5, PM4, PM10, or TSP* without disassembly and external cyclones

  • 90-degree light scattering photometer
    • Mass concentration engine provides real-time particulate measurement and display

  • Built-in compensating sample pump
    • Simultaneous gravimetric sampling on a 25 or 37-mm filter internal cassette

  • Smart auto-recognized toxic gas sensors
    • Carbon dioxide trending algorithms for calculation of room air exchange rates (with QuestSuite Pro II Software, see ordering information)

  • Displays Level, Minimum, Maximum, Average, STEL, and TWA in 6 languages

  • Trend graphing for all parameters

  • Menu-driven user interface with 10 push buttons/4 softkeys

  • Time history datalogging

  • Specialized models available for IAQ analysis and particulate monitoring (within the instrument’s measurement range)

Monitor multiple air quality hazards/parameters using one instrument with the Quest® EVM-7 environmental monitor. EVM-7 simultaneously measures particulates, volatile organic compounds (VOCs) with PID, toxic gas, carbon dioxide, relative humidity, temperature, and air velocity (with accessory probe). Two instruments in one means lower cost of ownership and elimination of multiple instruments.

Additional EVM-7 Features:

  • Factory calibrated relative to ISO 12103-1, A2 (Arizona Road Dust)


  • Site correction factors for particulates (user supplied)


  • Auto run and security code protection for unattended monitoring


  • Real-time measurement with once-per-second update rate


  • User selectable digital output for external functions
EVM Open showing Filter Cassette
EVM Sensor Bar Open
Easy access to gravimetric
sample filter cassette
Removable sensor bar for
easy access to sensors

EVM-7 Applications

  • Worksite monitoring
  • Industrial hygiene surveys
  • Military site evaluation
  • Aircraft and train environment sampling
  • Construction/mining site monitoring
  • Engineering studies
  • Industrial fenceline monitoring
  • Remediation sampling
  • IAQ walk-through and stationary studies
  • Air quality assessment
  • VOC screening and monitoring
  • Regulatory compliance

Specialized EVM Models
EVM-4 and EVM-3 feature the durability, quality, and overall design of the EVM-7, but provide a sensor configuration for specific applications.

  • EVM-4 for Comprehensive IAQ Analysis Monitors and logs CO, RH, temperature, and CO2 (with QuestSuite Pro II Software). Optional sensor accessories are available for air velocity, VOCs, particulates, and an alternate toxic gas.

  • EVM-3 Real-time Direct-reading Particulate Monitor Measures and logs particulate mass concentration (PM2.5, PM4, PM10, or TSP*), temperature, and RH. Optional sensor accessories are available for air velocity, CO2, VOCs, and CO or other toxic gas

Performance Profile

Method
Base Units
Display Res.
Display Range
Accuracy/Repeatability
Particulates
Light-scattering Photometer
mg/m3
0.001
0.000-199.9
± 15% (rel ARD)
Particulates Size Range
µm
N/A
0.1-10
*
VOCs
10.6 eV PID
ppm
0.01
0.00-2000
± 5%/2% (rel to Isobutylene) at calibration level
Carbon Dioxide
NDIR
ppm
1
0-20,000
± 2% of signal, ± 50 ppm between 0 and 2500
Toxic Gas (Electrochemical Sensors)
Carbon Monoxide
ppm
1
0-1000
± 5%/2% of signal
Chlorine
ppm
0.1
0.0-20
± 5%/2% of signal
Ethylene Oxide
ppm
0.1
0.0-20
± 5%/2% of signal
Hydrogen Cyanide
ppm
0.1
0.0-50
± 5%/2% of signal
Hydrogen Sulfide
ppm
1
0-500
± 5%/2% of signal
Nitric Oxide
ppm
0.1
0.0-100
± 5%/2% of signal
Nitrogen Dioxide
ppm
0.1
0.0-50
± 5%/2% of signal
Oxygen
%
0.1
0.0-30
± 5%/2% of signal
Sulfur Dioxide
ppm
0.1
0.0-50
± 5%/2% of signal
Temperature
Junction Diode
deg C
0.1
-10.0-60.0
± 1.1 deg C
deg F
0.1
14.0-140.0
± 2 deg F
Relative Humidity
Capacitive
% humidity
0.1
0.0-100
± 5% RH of signal between 10 and 90%
Air Velocity
Omni-directional Heated Thermistor Windprobe
m/sec
0.1
0.0-20
± 0.12 m/s + 4.5% of signal
ft/min
1
0-3940
± 23.6 ft/min + 4.5% of signal
General
Size Fractions PM2.5, PM4, PM10, or TSP*
Sample Pump Flow Rate 1.7 L/min
Power/Run Time Rechargeable Li-Ion battery pack provides minimum of 8 hrs of continuous operation
Weight 2.9 lb (1.3 kg)
Standards CE marked and RoHS compliant
Arizona Road Dust (ARD)
* The photometer can detect particles up to 100 µm; however, accuracy is reduced for sizes greater than 10 µm.

QuestSuite Pro II System Software
Expand data management and reporting capabilities for NoisePro, SoundPro SE & DL, HavPro, and QUESTemp° 34/36 instruments with QuestSuite Pro II (QSPII) Software. Manage an entire instrument inventory, including non-Quest instruments, from one easy-to-use software application. Program QuestSuite Pro II Software to automatically prompt when calibrations are due for inventory instruments. QuestSuite Pro II allows email direct from an error screen to technical support. Data deletion, import, and export occur at increased speed and data export to network drives is facilitated. Single and multiple user licenses are available. Contact SKC for multiple user information.


Ordering information

EVM Monitors
Cat. No.
EVM-7 IAQ/Dust Monitor with 5 Sensors: VOCs, CO2, Dust, Temperature, and Humidity includes datalogging monitor with sensors for VOCs (PID), CO2, particulates, temperature, and humidity (with air probe input connector), two 37-mm filter cassettes (for pump protection), 12-volt DC universal power supply, USB cable, silicone dielectric grease, PID cleaning kit, 10-pack pump protection filters, dust zero calibration assembly, toxic gas calibration adapter, and storage case

Purchase Air Probe-10 Air Velocity Probe separately.
EVM-7 CO/IAQ/Dust Monitor with 6 Sensors: VOCs, CO2, CO, Dust, Temperature, and Humidity includes datalogging monitor with sensors for VOCs (PID), CO2, CO, particulates, temperature, and humidity (with air probe input connector), two 37-mm filter cassettes (for pump protection), 12-volt DC universal power supply, USB cable, silicone dielectric grease, PID cleaning kit, 10-pack pump protection filters, dust zero calibration assembly, toxic gas calibration adapter, and storage case

Purchase Air Probe-10 Air Velocity Probe separately.
EVM-4 IAQ Monitor with 3 Sensors: CO2, Temperature, and Humidity includes datalogging monitor with sensors for CO2, temperature, and humidity (with air probe input connector), 12-volt DC universal power supply, toxic gas calibration adapter, USB cable, and storage case

Purchase Air Probe-10 Air Velocity Probe separately.
EVM-4 CO/IAQ Monitor with 4 Sensors: CO2, CO, Temperature, and Humidity includes datalogging monitor with sensors for CO2, CO, temperature, and humidity (with air probe input connector), 12-volt DC universal power supply, toxic gas calibration adapter, USB cable, and storage case

Purchase Air Probe-10 Air Velocity Probe separately.
EVM-3 Dust Monitor with 3 Sensors: Dust, Temperature, and Humidity includes datalogging monitor with sensors for particulates, temperature, and humidity (with air probe input connector), two 37-mm filter cassettes (for pump protection), 12-volt DC universal power supply, USB cable, silicone dielectric grease, 10-pack pump protection filters, dust zero calibration assembly, and storage case

Purchase Air Probe-10 Air Velocity Probe separately.
Dummy Sensor, seals empty sensor socket
Carbon Monoxide Smart Sensor
Chlorine Smart Sensor
Ethylene Oxide Smart Sensor
Hydrogen Cyanide Smart Sensor
Hydrogen Sulfide Smart Sensor
Nitric Oxide Smart Sensor
Nitrogen Dioxide Smart Sensor
Oxygen Smart Sensor
Sulfur Dioxide Smart Sensor
AirProbe-10 Air Velocity Kit includes AirProbe-10, mounting bracket, adapter cable, AC charger, and carry case
120 V
220 V
QuestSuite Professional II System software single user license
For additional user authorization codes, contact SKC.

Additional accessories are available. Contact SKC.

 

EVM Monitor Spec. Sheet (PDF)


This page was last modified June 14, 2010
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified July 28, 2010

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc