SKC Inc. The World Leader in Sampling Technologies
English
Espanol
Deutsch
Francais
Portugues
systransoft.com
  Headlines:
          New! SKC Webinars/Podcast
    
Deal of the Month.  Special pricing Click Here

HAZ-SCANNER EPAS
Wireless Environmental Perimeter Air Station

  • Direct reading

  • Haz-Scanner EPAS
  • Build your own station with up to 14 simultaneous air measurements including U.S. EPA criteria air pollutants
    • Standard configuration measures PM10 or TSP particulates, VOCs (PID), wind speed and direction, temperature, and relative humidity
    • Add one or all optional plug and play sensors (up to 4) and/or EPAS-specific meters (up to 4) as listed below. Choose from additional toxic gas (including hydrocarbons and methane) and biological/chemical agent sensors and EPAS-specific meters for solar radiance/UV or IR, barometric pressure, sound/noise, atomic radiation, ELF radiation, and rain
    • Available analog input port for alternative meter
    • Interchangeable size-selective impactors are available for PM1.0, PM2.5, or PM4.0 (close approximation of respirable)

  • Real-time readings, datalogging capabilities
    • Optional wireless data transmission up to 5 miles (line of sight)
    • Optional Ethernet Internet connection for 24/7 data reporting

  • Easily portable and deployable

  • Battery operated

  • Network up to 8 EPAS to one central PC or Mac

  • Easy-to-use graph and reporting software compatible with PC and Mac

Haz-Scanner Downloads

Haz-SCANNER EPAS shown with optional solar panels

The portable HAZ-SCANNER™ EPAS wireless environmental perimeter air station is easily deployed as an ambient air quality monitor to scan, measure, and document critical EPA criteria pollutants including nitrogen dioxide, sulfur dioxide, ozone, carbon dioxide, particulates, VOCs, and more. The EPAS provides direct readings in real time with datalogging capabilities. Contact an SKC product specialist to build your EPAS including up to 14 simultaneous critical air measurements in one battery-operated instrument.

 

HAZ-SCANNER Wireless EPAS Applications

  • Ambient air quality monitoring
  • Hazardous incident response
  • Complement to regulatory compliance
  • Waste site remediation
  • Military/homeland security
  • Perimeter monitoring
Haz-SCANNER EPAS shown with optional solar panels

HAZ-SCANNER software screen

Measure up to 14 critical air parameters with HAZ-SCANNER EPAS.

 

Configure an EPAS for Up to 14 Simultaneous Measurements
The standard HAZ-SCANNER EPAS includes the monitor (calibrated for ambient air applications) with sensors/meters for PM10 or TSP, VOCs, temperature, humidity, and wind speed/direction in a NEMA 4 enclosure, acid gas scrubber, internal battery, universal 110-240 V AC battery charger, software, cables, and CD with instructions.

Configure the monitor with additional sensors/meters — up to 4 optional plug and play sensors and/or up to 4 EPAS-specific meters (listed below). See the HAZ-SCANNER EPAS Product Data Bulletin (PDF) for specifications. Specify sensors and meters when ordering.

  • PM1.0, 2.5, or 4.0 (optional)
  • PM10 or TSP (standard)
  • VOCs (PID) (standard)
  • Ammonia (EC) (optional)
  • Carbon Dioxide (NDIR) (optional)
  • Carbon Monoxide (EC) (optional)
  • Chlorine (EC) (optional)
  • Hydrocarbon (methane-specific, EC) (optional)
  • Hydrocarbons (EC) (optional)
  • Hydrogen Cyanide (EC) (optional)
  • Hydrogen Sulfide (EC) (optional)
  • Nitric Oxide (EC) (optional)
  • Nitrogen Dioxide (optional)
  • Oxygen (optional)
  • Ozone (optional)
  • Sulfur Dioxide (optional)
  • Rain (optional)
  • Temperature (standard)
  • Relative Humidity (standard)
  • Solar Radiance (optional)
  • Sound and Noise (optional)
  • Atomic Radiation (optional)
  • ELF Radiation (optional)
  • Wind Speed/Direction (standard)
  • Barometric Pressure (optional)
  • Dew Point Temperature (optional)
  • Wet Bulb Temperature (optional)

Contact SKC to build an EPAS with available sensors/meters/ calibration for your application!

Performance Profile
The HAZ-SCANNER EPAS is optimized for ambient air quality applications; custom calibration for specific ranges or applications is available upon request. Build the station you need for your application.

HAZ-SCANNER EPAS Instrument Specifications
Display LCD real time
Operation 4-key splash-proof membrane switch
Power 12-V Absorption Glass Mat (AGM) battery
Operating Time 20 hrs (standard battery), continuous with AC or optional solar panels
Display Measurements Max, Min, TWA, STEL
Recording Time 1 sec to 21 weeks
Sampling Rate 1 sec, 1 min, 10 min, 1 hr, adjustable
Data Storage 454,545 data points
Sampling Pump 1.0 to 3.0 L/min
Digital Output RS-232 (PC), RS-423 (Mac)
Software PC or Mac
Dimensions (weather-proof case) 6 x 14 x 10 in (15.2 x 35.6 x 25.4 cm)
Weight 12 lbs (5.4 kg)
Operating Temperature -4 to 140 F (-20 to 60 C)
Storage Temperature -40 to 140 F (-40 to 60 C)
Humidity 95% non-condensing (use inlet heater)
Wireless Radio Modem 900 MHz (U.S.), 868 MHz (Euro) up to 5 miles - line of sight (optional)
Auxiliary Analog Input 0 to 2.5 VDC (1 channel for alternative meter)
* Note: All methane and non-methane hydrocarbon sensors are not approved for intrinsically safe applications. Do not use in explosive gas environments.

Ordering Information
The HAZ-SCANNER EPAS wireless environmental perimeter air station is a custom item. Contact SKC to build your own station.

HAZ-SCANNER EPAS Product Data Bulletin (PDF)

HAZ-SCANNER EPAS Wireless Environmental Perimeter Air Station Video

Haz-Scanner EPAS User Manual (PDF)

Haz-Scanner Quick Start Guide (PDF)

HazComm Software Manual (PDF)


This page was last modified September 8, 2011
  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified February 9, 2012
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2012 SKC Inc