SKC: Shaping the Future of Air Sampling  
 
 Español
 Deutsch
 Français
 Portuguese
 

 

 

Particulate Samplers, Dust Samplers, Cyclones, Impactors, and IOMs

Click on a link below to learn more about Particulate Samplers, Dust samplers, Cyclones, and IOMs from SKC
Aluminum Cyclone

SKC Aluminum Cyclone

The SKC Aluminum Cyclone is a lightweight respirable dust sampler that is used with a filter loaded into a three-piece filter cassette. The SKC cyclone gives sharp size selection between respirable fractions at 4 or 5 µm.

SKC Button Sampler for Inhalable Dust

SKC Button Sampler for Inhalable Dust

The SKC Button Aerosol Sampler is a reusable filter sampler with a porous curved-surface sampling inlet designed to improve the collection characteristics of inhalable dust. The SKC Button Sampler meets the ACGIH/ISO sampling criteria for inhalable particulate mass. See also the SKC Abrasive Blasting Sampler for Heavy Metals

Diesel Particulate Matter  Cassette

Diesel Particulate Matter: Samplers and Cassettes

sampling equipment that meets the requirements of NIOSH 5040 or MSHA specifications for sampling Diesel Particulate Matter (DPM).

DPS (Deployable Particulate Sampler ) System

The Most Portable 10 L/min Ambient PM10 Sampling System Available. SKC has brought portability, cost effectiveness, and ease of use to ambient PM10 sampling with the SKC Deployable Particulate Sampler (DPS) System. SKC has combined its fully programmable Leland Legacy® Sample Pump with the DPS-10 Impactor and sampling accessories to create this convenient turnkey system.


SKC IMPACT Sampler

The SKC IMPACT single-stage inertial impactor is designed for the efficient collection of PM10 or PM2.5 in ambient air. A sampling pump operating at 10 L/min draws PM through the impactor; larger particles are captured on a disposable pre-oiled impaction substrate while smaller particles collect on a 47-mm filter.


GS-3 Cyclone

GS-3 Cyclone

The GS-3 Cyclone is a 10 mm, lightweight, 2-piece conductive plastic unit that holds a standard 37 mm filter cassette for collecting respirable dust particles. The GS-3 cyclone is designed to meet the ACGIH/CEN/ISO Curve.

GS-1 Cyclone

GS-1 Cyclone

The GS-1 Cyclone, a single-inlet version of the GS-3 Cyclone, provides performance equivalent to the Dorr-Oliver Cyclone, but has the added advantage of being constructed of conductive plastic

IOM Inhalable Dust Sampler

IOM Inhalable Dust Sampler

The IOM sampler is a reusable filter cassette with a sampling head designed to better measure the worker's exposure to total airborne particulates.

Parallel Particle Impactor (PPI)

Only the SKC Parallel Particle Impactor (PPI) has the power of 4 impactors in 1 small sampler to provide the closest match to the ACGIH/ISO/CEN thoracic or respirable curves. A job no single personal impactor can do alone!

PEM: Personal Environmental Monitor

PEM: Personal Particulate Sampler

The Personal Environmental Monitor (PEM) is a lightweight, personal sampling device for collecting particulates of either 2.5 or 10 µm aerodynamic equivalent diameter.

SKC Personal Modular Impactors (PMIs)

SKC Personal Modular Impactors (PMIs) are designed for the highly efficient collection of PM10, PM2.5, or PM Coarse(PM10-2.5).

Sioutas Cascade Impactor

Sioutas Cascade Impactor

The personal-size Sioutas Cascade Impactor separates and collects airborne particles in five size ranges. he Sioutas Impactor is highly efficient at collecting particles without the use of impaction grease or substrate coatings and at retaining labile compounds for size-fractionated chemical analysis.


 

Developments in Inhalable Samplers


Particulate Monitors


3886 Handheld Laser Particle Counter

Handheld Laser Particle Counter

The 3886 Handheld Laser Particle Counter simultaneously monitors five particle size channels to provide concentration measurement of 0.3, 0.5, 1.0, 3.0, and 5.0-micron particles. Add optional probes for relative humidity/temperature and air velocity for simultaneous monitoring of these important indoor air parameters.


EPAM-5000

EPAM-5000 Environmental Particulate Monitor

The EPAM-5000 particulate air monitor is available in three different kit configurations: a 10 µm kit, 2.5 µm kit, and a 1.0 µm kit. Each kit contains the EPAM-5000 monitor with a specific cut-point sampling head, battery charger, HazComm PC software and computer cable, shoulder strap, and manual.

Haz-Dust 1 Real-time Area Dust Monitor

Haz-Dust ™ Real-time Area Dust Monitor

The HAZ-DUST is a real-time dust monitor designed for industrial hygiene studies, HazMat investigations, and remediation projects.

HAZ-DUST IV Aerosol Monitor

The HAZ-DUST IV personal real-time aerosol monitor, with new infrared detector, provides you with immediate breathing zone measurements of aerosol and dust for industrial hygiene and environmental air investigations. The small, lightweight unit attaches onto a worker's belt while the miniature sensor easily clips to a worker's collar. Select from inhalable, thoracic, or respirable sampling heads to target a specific fraction. An in-line 37-mm cassette behind the sensor allows the user to collect a concurrent filter sample for gravimetric or chemical analysis.


HAZ-DUST VDM-7500 Wireless Personal Video Dust Monitoring System

Digitally record workplace dust exposure with the HAZ-DUST VDM-7500 wireless video dust monitoring system. The VDM-7500 measures levels of lung-damaging particles while simultaneously overlaying dust concentration onto video images.


MEM: Micro-Environmental Monitor

MEM: Micro-Environmental Monitor

The Micro-Environmental Monitor (MEM) is a line-operated compact aerosol sampling system for collecting particulates of either 2.5 or 10 µm aerodynamic equivalent diameter.

Split2 Dust Monitor

Split2 Real-time Personal or Area Dust Monitor

The economical and easy-to-use SPLIT2 Dust Monitor is designed for personal or area monitoring for respirable, thoracic, or inhalable dust. SPLIT2 is a passive dust monitor that can become an active monitor by combining it with a 2 L/min sample pump and GS Cyclone or IOM sampling head for dust monitoring and concurrent dust sampling

This page was last modified April 30, 2008
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified January 6, 2008

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000