SKC |
 |
SKC
Button Sampler for Inhalable Dust
SKC Button Aerosol Sampler
is a filter sampler with a porous curved-surface inlet designed
to improve the collection characteristics of inhalable dust
(< 100-µm aerodynamic diameter), including bioaerosols
for total (viable plus non-viable) microbial count. |
| |
 |
Cyclone:
GS-1 for Respirable Dust
The GS-1 Cyclone, a single-inlet version of the GS-3 Cyclone,
provides performance equivalent to the Dorr-Oliver Cyclone but has
the
added advantage of being constructed of conductive plastic. |
| |
 |
Cyclone:
GS-3 for Respirable Dust
The GS-3 Cyclone is a 10-mm lightweight two-piece conductive
plastic unit that holds a standard 37-mm filter cassette for collecting
respirable dust particles. The GS-3 Cyclone is designed to meet
the ACGIH/CEN/ISO respirable convention. |
| |
 |
Cyclone: Conductive
Plastic for Respirable Dust
The SKC Plastic Cyclone is a lightweight conductive plastic unit
that holds a collection filter in a reusable cassette during
sampling. It is designed for a 50% cut-point of 5.0 µm
at 1.9 L/min and 4.0 µm at 2.2 L/min. |
| |
 |
Cyclone:
Aluminum Cyclone for Respirable Dust
The SKC Aluminum Cyclone is a lightweight respirable dust sampler
that is used with a filter loaded into a three-piece filter cassette.
The SKC cyclone gives sharp size selection between respirable fractions
at 4 or 5 µm. |
| |
 |
Diesel
Particulate Matter (DPM): Samplers and Cassettes for Sub-micron
Dust
DPM samplers and cassettes meet the requirements of NIOSH
5040 or MSHA specifications for sampling diesel particulate matter. |
| |
 |
DCS
(Deployable Cartridge Sampler) System for PAHs/PHDDs/PHDFs/Associated
Particulate
The
SKC DCS System is ideal
for portable sampling of gaseous PAHs, PHDDs, PHDFs, and particulate-associated
PHDDs and PHDFs in ambient air. The kit features the fully programmable
Leland Legacy Sample Pump with high-power Li-Ion battery for
over 24 hours of run time. Specially designed sampling heads
are easily loaded with media and deployed. Accessories such as
a quick-mount bracket and quick-connect tubing provide for convenient
setup.
|
| |
 |
DPS
(Deployable Particulate Sampler) System for Ambient PM10
or PM2.5
The most portable
10 L/min Ambient PM10 sampling system available. SKC has
brought portability, cost effectiveness, and ease of
use to ambient PM10 sampling with the SKC DPS System. SKC
has combined its fully programmable Leland Legacy® Sample
Pump with the DPS-10 Impactor and sampling accessories to
create this convenient turnkey system. |
| |
 |
IMPACT
Sampler for PM10, PM2.5, PM Coarse
The SKC IMPACT single-stage inertial impactor is designed
for the efficient collection of PM10 or PM2.5 in ambient air.
A sampling pump operating at 10 L/min draws PM through the impactor;
larger particles are captured on a disposable pre-oiled impaction
substrate while smaller particles collect on a 47-mm filter.
|
| |
 |
IOM
Sampler for Inhalable Dust
The IOM sampler is a reusable filter cassette with a sampling
head designed to better measure the worker's exposure to total
airborne particulates. |
| |
 |
Parallel Particle
Impactor (PPI) for Thoracic or Respirable Dusts
Only the SKC Parallel Particle Impactor has the power of 4
impactors in 1 small sampler to provide the closest match to the
ACGIH/ISO/CEN thoracic or respirable conventions. A job no single
personal impactor can do alone! |
| |
 |
PEM:
Personal Particulate Sampler for PM10 or PM 2.5
The Personal Environmental Monitor (PEM) is a lightweight,
personal sampling device for collecting particulates of either
2.5 or 10-µm aerodynamic equivalent diameter. |
| |
 |
SKC Personal Modular
Impactors (PMIs) for PM10, PM2.5, or PM Coarse
SKC Personal Modular Impactors are designed for the highly
efficient collection of PM10, PM2.5, or PM Coarse (PM10-2.5). |
| |
 |
Sioutas
Cascade Impactor for Coarse, Fine, and Ultrafine Particles
The personal-size Sioutas Cascade Impactor separates
and collects airborne particles in five size ranges. The Sioutas
Impactor is highly efficient at collecting particles without the
use of impaction grease or substrate coatings and at retaining
labile compounds for size-fractionated chemical analysis. |
|

|
Environmental
Devices Instruments
|
 |
AIR-AIDE Airborne
Particulate Monitor for PM10, PM2.5, PM 1.0, or ISO Respirable
(4.0 µm)
The portable AIR-AIDE™ Airborne Particulate Monitor
is a fixed-point monitor for measuring lung damaging dust levels.
AIR-AIDE is ideal for indoor air quality investigations and as
a tool for compliance. With the 10-hour NiMH battery, AIR-AIDE
can sample for a full day. For extended monitoring, run AIR-AIDE
from AC power using the supplied charger/adapter. Results are
displayed immediately or can be stored in memory. At the end
of monitoring, download data to a PC. Supplied DustComm Pro Software
allows for graphical and statistical representation of the total
dust generating process.
|
| |
 |
EPAM-5000
Environmental Particulate Monitor for PM10, PM2.5, or PM
1.0
The HAZ-DUST EPAM-5000 particulate air monitor is available
in kits with a 10, 2.5, or a 1.0-µm sampling head. Each
kit contains the EPAM-5000 monitor with a specific cut-point
sampling head, battery charger, HazComm PC software and computer
cable, shoulder strap, and manual.
|
| |
 |
HAZ-DUST
I Real-time Area Dust Monitor for Respirable or Thoracic
PM
The HAZ-DUST is a real-time dust monitor designed for industrial
hygiene studies, HazMat investigations, and remediation projects.
|
| |
 |
HAZ-DUST
IV Personal Aerosol Monitor for Inhalable, Thoracic, or Respirable
PM
The HAZ-DUST IV personal real-time aerosol monitor, with
new infrared detector, provides you with immediate breathing
zone measurements of aerosol and dust for industrial hygiene
and environmental air investigations. The small, lightweight
unit attaches to a worker's belt while the miniature sensor easily
clips to a worker's collar. Select from inhalable, thoracic,
or respirable sampling heads to target a specific fraction. An
in-line 37-mm cassette behind the sensor allows the user to collect
a concurrent filter sample for gravimetric or chemical analysis.
|
| |
 |
HAZ-DUST
VDM-7500 Wireless Personal Video Dust Monitoring System for
Inhalable, Thoracic, or Respirable PM
Digitally record workplace dust exposure with the HAZ-DUST
VDM-7500 wireless video dust monitoring system. The VDM-7500 measures
levels of lung-damaging particles while simultaneously overlaying
dust concentration onto video images. |
| |
 |
SPLIT2
Real-time Personal or Area Dust Monitor for Inhalable or
Respirable Dust
The economical and easy-to-use SPLIT2 Dust Monitor is designed
for personal or area monitoring for respirable, thoracic, or
inhalable dust. SPLIT2 is a passive dust monitor that can become
an active monitor by combining it with a 2 L/min sample pump
and GS Cyclone or IOM sampling head for dust monitoring and concurrent
dust sampling
|
|
 |
Quest Instruments
|
 |
EVM Environmental Monitors
for Particulate and Gas Measurement
Monitor and log particulate mass and gas concentration simultaneously
with the Quest™ EVM-7 monitor. Use the twist and click
impactor to select PM2.5, PM4, PM10, or TSP. The EVM-3 monitors
and logs particulate mass, temperature, and relative humidity.
|
|