ACCU-CAP
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
1. Simply open a two-piece cassette and insert a support pad on the bottom section (outlet). |
![]() |
2. Insert the ACCU-CAP with the bubble facing up. |
![]() |
3. Press on the top section (inlet) of the cassette. The opening on top of the ACCU-CAP aligns with the inlet opening of the cassette. |
The ACCU-CAP Advantage
Using ACCU-CAP Cassette Inserts
ACCU-CAP cassette inserts are used with a two-piece cassette with
support pad. Simply open the cassette and insert ACCU-CAP between
the cassette's inlet and outlet sections. Sample as you would with
a filter in a closed-faced filter cassette and according to method
specifications.
One ACCU-CAP capsule retains the entire sample. The total weight
of the ACCU-CAP capsule is <300 mg for the 37-mm and <200
mg for the 25-mm
ACCU-CAP Means No Sample Loss
Problem: Dust particles such as powders, wood, and light metals become statically charged due to the manner in which they are generated, i.e., during grinding, woodworking, or cutting. Sample loss can occur when these statically charged airborne particles are drawn into a plastic cassette and adhere to the inside of the cassette. To resolve this, cassettes are sometimes rinsed to remove the particles from the sides. However, this step can result in a diluted sample. Another point of sample loss due to static buildup is during removal of the filter from the cassette. Particles may be pulled off the filter and remain in the cassette.
Solution: ACCU-CAP! With ACCU-CAP, the entire particle sample is captured inside the one-piece ACCU-CAP capsule. No loss here! ACCU-CAP is also versatile; If an in situ contaminant extraction is required, perform it easily inside the ACCU-CAP capsule.
Filter Choices for ACCU-CAP
ACCU-CAP is available with the following filters:
Performance Profile
| Diameter: | 25 mm or 37 mm |
| Weight: | 25 mm is >200 mg 37 mm is >300 mg |
| Analysis: | Gravimetric |
Ordering Information
| 25-mm ACCU-CAP Inserts | Qty.
|
Cat. No. |
| 0.8 µm pore size, MCE filter | ||
| 37-mm ACCU-CAP Inserts | Qty.
|
Cat. No. |
| 0.8 µm pore size, MCE filter | ||
| 5.0 µm pore size, PVC filter |
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |