SKC Coated Filters
Pretreated, Preloaded, and Prebanded
- Ready to use
- Time-saving
- Convenient alternative to impinger wet chemistry
methods
- Economical
- No assembly required
- Preloaded into cassettes
- Sealed with end plugs and shrink bands
- Meet agency method specifications
- No cumbersome collection liquids or glass
- Easy personal sampling
- Small package size for short shelf-life product
|
|
Coated filters make sampling reactive compounds fast and easy.
They are a convenient alternative to wet chemistry methods using
impingers. Simply unplug the lightweight cassette, insert it into
an SKC Filter Cassette Holder, clip holder to a worker’s collar,
and attach to a personal sampling pump. Use coated filters to collect
compounds that exist as an aerosol or mist or for some higher boiling
vapors. Flow rates are typically greater than 1 L/min and sampling
times range from 15 minutes to one hour. Most coated filter samples
are extracted in solvents and analyzed by gas or liquid chromatography.
SKC offers coated filters to meet a variety of OSHA, NIOSH, ASTM,
and international agency methods.
ISO-CHEK Coated Filter System Developed for Isocyanates
Traditional methods for isocyanate collection (NIOSH 5521 with impinger
and OSHA 42 with 1-2PP impregnated filter) yielded samples that
were susceptible to degradation under ambient conditions, required
time-consuming sample preparation, and provided ambiguous results.
The IRSST (Institut de recherché Robert-Sauvé en
santé et en sécurité du travail du Québec)
minimized these problems by developing and patenting the ISO-CHEK
Sampling System. The ISO-CHEK dual-filter cassette captures isocyanate
aerosols and vapors simultaneously and separately at the point
of collection. This collection method is highly stable, allows
rapid sampling, and provides for highly sensitive physical and
chemical characterization of isocyanates.
Ordering Information
Coated Filter Selection Chart
For Agency Methods
| Chemical |
Method* |
Filter
and Coating
37-mm cassette with shrink bands
Coated filters have a limited shelf-life |
Notes |
Qty. |
Cat.
No. |
| Acetic anhydride |
OSHA 82 |
2 Glass filters; 1-(2-pyridyl) piperazine
4-piece, 37-mm cassette
|
1 |
10 |
225-9009 |
| Acetic anhydride |
OSHA 102 |
2 Glass filters; veratrylamine
and di-n-octyl phthalate
4-piece, 37-mm cassette |
3 |
10 |
225-9010 |
| 4-Aminobiphenyl |
OSHA 93 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Aniline |
NIOSH 2017 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
6 |
10 |
225-9004 |
Arsenic, inorganic
(volatile compounds as As) |
OSHA ID-105 |
1 MCE filter and cellulose pad; sodium carbonate
3-piece, 37-mm cassette |
|
10 |
225-9001 |
| Benzidine |
OSHA 65 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Bromine |
NIOSH 6011 |
1 PTFE pre-filter and polypropylene
support; specially cleaned silver membrane and polypropylene
support
3-piece, 25-mm cassette |
|
5 |
225-9006 |
| Chlorine |
NIOSH 6011 |
1 PTFE pre-filter and porous plastic support;
specially cleaned silver membrane and porous plastic support
3-piece, 25-mm cassette |
|
5 |
225-9006 |
| Crotonaldehyde |
OSHA 81 |
2 Glass filters; 2,4-dinitrophenylhydrazine and
phosphoric acid
3-piece, 37-mm cassette |
1 |
10 |
225-9019 |
| o-Dianisidine |
OSHA 71 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 3,3'-Dichlorobenzidine |
OSHA 65 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
Diisocyanates
1,6-Hexamethylene diisocyanate (HDI),
Toluene-2,4-diisocyanate (2,4-TDI),
Toluene-2,6-diisocyanate (2,6-TDI) |
OSHA 42 |
1 Glass filter and cellulose support;
1-(2-pyridyl) piperazine
3-piece, 37-mm cassette |
1,4 |
10 |
225-9002 |
| 1,3,4 |
10 |
225-9013 |
Diisocyanates
Toluene-2,4-diisocyanate (2,4-TDI),
Toluene-2,6-diisocyanate (2,6-TDI) |
ASTM
D5836† |
1 Glass filter and cellulose support;
1-(2-pyridyl) piperazine
3-piece, 37-mm cassette |
1,4 |
10 |
225-9002 |
| 1,3,4 |
10 |
225-9013 |
| Diphenylamine |
OSHA 78 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette
|
|
10 |
225-9004 |
| Fluorides |
OSHA ID-110
NIOSH 7902
NIOSH 7906
ASTM D4765 |
1 MCE filter and cellulose pad; sodium carbonate
3-piece, 37-mm cassette |
8 |
10 |
225-9001 |
| Fluoride, particulates |
EPA 14A
not
EPA TO-14A |
2 PVC filters and supports; sodium formate/Metricel
filter; uncoated
4-piece, 37-mm cassette |
|
10 |
225-9016 |
| Glutaraldehyde |
OSHA 64 |
2 Glass filters; 2,4-dinitrophenyl hydrazine and
phosphoric acid
4-piece, 37-mm cassette |
1 |
10 |
225-9003 |
| Hydrazine |
OSHA 108 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9012 |
Isocyanates
Toluene-2,4-diisocyanate (2,4-TDI),
Toluene-2,6-diisocyanate (2,6-TDI),
Hexamethylene diisocyanate |
ASTM D5932
ASTM D6561
ASTM D6562 |
1 PTFE filter, 1 Glass Fiber filter
treated with MAMA
(ISO-CHEK Sampling System)
3-piece, 37-mm cassette |
5 |
12 |
225-9022 |
5 |
36 |
225-9022A |
Isocyanates, organic
|
MDHS 25/3 (UK) |
AE Glass filter; methoxyphenyl piperazine
25-mm filters only, not in preloaded cassettes |
1,7 |
5 |
225-9011 |
| N-Isopropylaniline |
OSHA 78 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Maleic anhydride |
OSHA 86 |
2 Glass filters; veratrylamine
3-piece, 37-mm cassette |
1 |
10 |
225-9021 |
Mercaptans
(methyl-, ethyl- , n-butyl-, and phenyl-) |
NIOSH 2542
OSHA 26
OSHA PV2075 |
1 Glass filter; mercuric acetate
2-piece, 37-mm cassette |
1 |
10 |
225-9007 |
| 4,4'-Methylene bis (2-chloroaniline) (MOCA) |
OSHA 71 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Methylene bisphenyl isocyanate (MDI) |
OSHA 47 |
1 Glass filter and cellulose support; 1-(2-Pyridyl)
piperazine
3-piece, 37-mm cassette |
1,4 |
10 |
225-9002 |
| 1,3,4 |
10 |
225-9013 |
| 4,4'-Methylenedianiline |
OSHA 57
NIOSH 5029 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 1-Naphthylamine |
OSHA 93 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 2-Naphthylamine |
OSHA 93 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Nitrobenzene |
NIOSH 2017 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
6 |
10 |
225-9004 |
| Ozone |
OSHA ID-214 |
2 Glass filters; nitrite-impregnated
3-piece, 37-mm cassette |
1,3 |
10 |
225-9014 |
Phenylenediamine
(o-, m-, p-) |
OSHA 87 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| Phosphine |
OSHA 1003 |
1 Glass filter; 1 polyester filter treated with
mercuric chloride
3-piece, 37-mm cassette |
1,3 |
10 |
225-9018 |
| Sulfur dioxide |
NIOSH 6004
(modified)
|
1 MCE pre-filter and support/1 cellulose filter and support;
sodium carbonate
3-piece, 37-mm cassette |
|
10 |
225-9005 |
| o-Tolidine |
OSHA 71 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 2,4-Toluendiamine |
OSHA 65 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 2,6-Toluendiamine |
OSHA 65 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| o-Toluidine |
NIOSH 2017 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
6 |
10 |
225-9004 |
Toluidine
(o-, m-, p-) |
OSHA 73 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
| 1,3,5-Triglycidyl Isocyanurate (TGI) |
OSHA PV2055 |
1Glass fiber filter; hydrobromic
acid |
3 |
10 |
225-9027 |
| Valeraldehyde |
OSHA 85 |
3 Glass filters; 2,4-dinitrophenylhydrazine and
phosphoric acid
3-piece, 37-mm cassette |
1 |
10 |
225-9020 |
m-Xylylenediamine,
p-Xylylenediamine
(m-XDA, p-XDA) |
OSHA 105 |
2 Glass filters; sulfuric acid
3-piece, 37-mm cassette |
|
10 |
225-9004 |
Table Notes
| 1 |
Storage below 39.2 F (4 C) required
|
| 3 |
Custom order due to very limited shelf-life
|
| 4 |
While meeting the specifications
of OSHA Methods 42 and 47, Coated Filter Cat. No. 225-9002 contains
a higher than
specified loading of reagent to increase stability and
shelf-life. Coated Filter Cat. No. 225-9002 traps both
vapor and aerosol phases. SKC also offers Coated Filter
Cat. No. 225-9013 that contains the specified reagent
loading for OSHA 42 and 47, but has a freezer shelf-life
of only three months.
|
| 5 |
Meets multiple ASTM methods:
ASTM D5932 for 2,4 and 2,6-TDI
ASTM D6561 for HDI
ASTM D6562 for HDI
|
| 6 |
NIOSH Method 2017 also requires SKC Sorbent Tube Cat. No.
226-15.
|
| 7 |
Filters only; not in preloaded cassettes
|
| 8 |
Collects both vapor and aerosol phases of fluorides. The concept
of sampling for fluorides in air using a double filter is patented
in Canada by IRSST (Institut de recherche en santé et Robert-Suavé en
sécurité du travail du Québec), 21-April-92, Patent No. 1,299,114.
|
| † |
ASTM D5836 and D5932 for 2,4-TDI, 2,6-TDI only
|
| * |
The methods listed are the most widely used. Additional methods
may be listed in the Sampling
Guide or use the search form below. |
Search for Methods for SKC Coated Filters
To search for methods which use a particular SKC Coated Filter,
enter the exact SKC Catalog Number in the search box.
| Chemical Name |
CAS No. |
Method |
Description and Cat. No. |
For detailed information of Methods refer to SKC's:
Coated
Filters in Preloaded Cassettes Spec. Sheet (PDF)
Material Safety Data Sheets
MSDS — MOPIP 1-(2-Methoxyphenyl)
Piperazine (PDF)
MSDS — MAMA 9-(Methylaminomethyl)
Anthracene (PDF)
MSDS — Toluene (PDF)
Custom Filters Available
For specific applications, SKC will manufacture filters to meet your
specific requirements. Download the Custom Filter Order Form in PDF
format. Complete the form and fax it to your SKC
representative, contact your SKC
representative, or call the SKC Sales Department at 724-941-9701
for more information.
Custom
Filters Order
Form (PDF)
This page was last modified May 12, 2010
|