PUF Tubes
For High-volume Sampling
SKC PUF Tube 226-129
SKC High-volume PUF Tubes are cleaned and
ready to use
PUF Tubes for High-volume Sampling Spec. Sheet
(PDF)
- Designed to meet EPA and ASTM method specifications for
high flow sampling of organochlorine pesticides, PCBs, and PAHs
in ambient air
- Use with flows from 200 to 280 L/min
- For measurements up to 24 hours
- Precleaned to meet method specifications
- Ready to use
- Suitable for repacking and recertification
- Custom PUF tubes available upon request
PUF Tube for Pesticides, PAHs, PCBs, and
PCDDs
EPA Methods TO-4A, IP-7, TO-9A,TO-13A,
and ASTM-D6209
This tube contains a 75-mm polyurethane foam (PUF) sorbent plug
and can be used with the General Metal Works PS1 Sampler. These tubes
are packed with cleaned PUF for low background. Use this high-volume
PUF tube to sample pesticides and polychlorinated biphenyls (PCBs)
according to EPA Method TO-4A, polyaromatic aromatic hydrocarbons
(PAHs) for EPA Method TO-13A, and polychlorinated dibenzo-p-dioxins
(PCDDs) to meet EPA Method TO-9A and polycyclic aromatic hydrocarbons
for ASTM D6209.
Catalog Number 226-131
PUF/XAD®-2 Tube for Pesticides,
PAHs, and PCBs
EPA Method 600/8-80-038
This high-volume PUF tube contains a 50-mm and a 25-mm section
of PUF with a 10-gram section of XAD-2 sorbent sandwiched between
the two PUF layers. XAD-2 sorbent improves volatile component extraction
during analysis. Use this tube to sample volatile pesticides and
Polynuclear aromatic hydrocarbons
(PAHs) as described in the EPA
Manual of Analytical Methods for the Analysis of Pesticides in Humans
and Environmental Samplers (EPA Method 600/8-80-038, June 1990).
This tube can be used with the General Metal Works PS1 Sampler.
Catalog Number 226-129
Quartz Filters for Use with High-volume PUF Tubes
Sample
air passes through a 102-mm filter to remove particles before it
enters the PUF tube. This filter is made of Tissuquartz which can
be used at temperatures up to 2000 F (1093 C).
Catalog Number 225-1821
High-volume PUF tubes and Accessories
Methods |
Compounds |
Sorbent
(Amount) |
Cat. No.
|
EPA 600/8-80-038 |
Organochlorine pesticides, PCBs |
PUF/XAD-2/PUF
(50 mm/10 gm/25 mm) |
226-129
|
| Non-agency * |
Nonpolar organic compounds |
EPA TO-4A, TO-9A,
TO-13A, IP-7 |
Organochlorine pesticides, PCBs, polyaromatic hydrocarbons
(PAHs) and PCDDs |
PUF
(75 mm) |
226-131
|
| ASTM D6209 |
Polycyclic aromatic hydrocarbons |
| Accessories
|
| Filters, Tissuquartz, high-purity
microfibers, 432-µm thick 102 mm; for sampling at high temperatures
up to 2000 F (1093 C), pk/25 |
225-1821
|
| Replacement PUFs/Repacks
|
| Replacement PUF for 226-129, uncleaned,
25-mm length, pk/10 |
P226129A
|
| Replacement PUF for 226-129, uncleaned,
50-mm length, pk/10 |
P226129B
|
| Replacement PUF for 226-131, uncleaned,
75-mm length, pk/10 |
P226131
|
| Replacement PUF for 226-131, cleaned,
75-mm length, pk/10 |
P226131C
|
| Repack for 226-129, new PUF/sorbent packed into cleaned
original glass and inserted into cleaned storage bottle |
P226129R
|
| Repack for 226-131, new PUF/sorbent packed into cleaned
original glass and inserted into cleaned storage bottle |
P226131R
|
| Glass Cartridge with support screens for 226-129 or
226-131, set |
P226129C
|
* Nonpolar Organic Compounds,
Analytical Chemistry, Vol 63, No. 13, July 1991, pp. 1228-1232
PUF
Tubes for High-volume Sampling Spec. Sheet (PDF)
This page was last modified May 27, 2011
|