OSHA Versatile Sampler Tubes
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
Available with a variety of sorbent and filter combinations, SKC OVS Tubes are truly versatile for sampling applications including pesticides such as DDVP (dichlorvos), carbaryl (Sevin®), chlorpyrifos (Dursban®), Diazinon®, malathion, and parathion; explosives such as TNT, DNT; alcohols such as glycols; and biocides.
Other combinations of sorbents or filters following the OVS tube design are available by special order for research or other specialty uses. Contact SKC Sales with your tube specifications.
Ordering Information
| Application - Methods | Sorbent (Amount) |
Filter |
Qty. |
Cat. No. |
| Pesticides OSHA 62, 63, 67, 70, 74, OSHA CSI Organotin Compounds (methyl tin mercaptide, stannous-2-ethyl hexaneoate, butyltin trichloride) OSHA CSI |
XAD®-2 (270/140 mg) |
Glass fiber |
pk/10 |
|
pk/50 |
226-30-16A | |||
| Pesticides Organophosphorous - NIOSH 5600, 5601, 5602 |
XAD-2 (270/140 mg) |
pk/10
|
||
pk/50
|
226-58A | |||
| Explosives (trinitrotoluene [TNT] and dinitrotoluene [DNT]) - OSHA 44 Phthalate esters OSHA 104 Acrylates and Benzophenone (Non-agency method) |
Tenax ® (140/70 mg) |
Glass fiber |
pk/10 |
|
| Caprolactum vapor OSHA CSI Glycols NIOSH 5523 |
XAD-7 (200/100 mg) |
Glass fiber |
pk/10
|
|
pk/50
|
226-57A | |||
Kathon® 886 (Biocide) |
Silica gel (520/260 mg) |
Glass fiber |
pk/10 |
226-99 |
Non-agency method
| | Nylander-French L.S., Priha E., Berglund G., and Rosen G., "A Method for Monitoring Worker Exposure to Airborne Multifunction Acrylates," Applied Occupational Environmental Hygiene, Volume 9, Number 12, pp. 977-983; 1994. |
| ‡ | Kathon® Biocide (2-Methyl-4-Isothiazolin-3-one
and 5-Chloro-2-Methyl-4-Isothiazolin-3-one) Sobczak, S.S, Rohm
and
Haas Corp., Industrial Hygiene Laboratory Method IH9901, 2001
Kathon is a trademark of Rohm and Haas Co. |
| OVS Tube Holder | |
The OVS Tube Holder consists of a standard tube holder fitted
with a special durable protective cover for the OVS tube. A
collar clip fastened to the protective cover allows for easy
attachment
to a worker. A flexible metal coil surrounds the tubing just
below the holder and allows the tubing to bend without blocking
the airflow. The OVS Tube Holder is suitable for use with Universal
XR, AirChek® 2000, and AirChek 52 sample pumps. OVS Tube Holder includes fitting with durable protective cover, 3 feet of tubing, and collar clip. |
|
| OVS Tube Holder Cat. No.........................................224-29V | |
| Tubing/Adapter Kit for Calibration of OVS Tubes |
| This new kit contains two sections of tubing and a tubing adapter to facilitate calibration of a sample pump when using an OVS Sorbent Tube. OVS Adapter Kit includes tubing and adapter for calibration of OVS tubes. |
| OVS Adapter Kit Cat. No.........................................224-31 |
| Multi-purpose Calibration Jar |
|
| The SKC Multi-purpose Calibration Jar provides convenient calibration when using a GS Cyclone, PUF tube, OVS tube, the IOM, or the PEM. Instead of packing four or five different calibration adapters for the field, pack only one Multi-purpose Calibration Jar. The rugged 32-ounce polypropylene jar contains a quick screw cap and barbed fitting for easy connection. | |
| Multi-purpose Calibration Jar Cat. No.........................................225-111 | |
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |