FluoroFilm Air Sample Bags
For Low-level Sampling with Analysis in < 1 Day

  • FluoroFilm FEP (fluorinated ethylene propylene) is the most chemically inert of all bag material


  • Very low VOC and sulfur background


  • Choice of all-in-one PTFE or stainless steel hose/valve and septum fitting


  • Mechanically strong 2-mil FEP — resists impact and tearing

  • Custom bags available


  • Why SKC Sample Bags image
Tedlar bags Available with Stainless Steel or PTFE fittings
Available with these fittings:
Single Stainless Steel Fitting
Single Stainless Steel
240 Fiting
Single PTFE

Sample bags made of FluoroFilm, the most chemically inert sample bag material, offer the ultimate performance in bag sampling. However, storage stability is more limited with FluoroFilm bags, so expedited analysis is necessary.

Use only PTFE tubing for bag sampling to prevent sample loss through adsorption to the tubing’s inner surface.

Sample bag maximum operating temperature can be dictated by the temperature tolerances of the bag material, fitting material, and/or fitting components such as O-rings.

  • SKC single stainless steel, dual stainless steel, and PTFE fittings: Maximum temperature is 225 F (107.2 C) due to the fitting O-ring.


  • SKC single polypropylene fitting: Maximum temperature is 200 F (93.3 C) due to the fitting material.


  • SKC FlexFilm sample bags: Maximum temperature is 140 F (60 C) due to the bag material.

Inert to a Broad Range of Chemicals
FluoroFilm is the most chemically inert of all the plastics. In fact, FluoroFilm is solvent-resistant to nearly all chemicals.

SKC FluoroFilm Air Sample Bags

Single PTFE Fitted FluoroFilm Bags*
Fitting Maximum Capacity
(liters)
Qty. Cat. No.
240 Fiting
Single PTFE
0.5 pk/5 240-02
1 pk/5 240-01
3 pk/5 240-03
Replacement Septa pk/10 233-01-RS
 
Single Stainless Steel Fitted FluoroFilm Bags*
Fitting Maximum Capacity
(liters)
Qty. Cat. No.
Single Stainless Steel Fitting
Single Stainless Steel
0.5 pk/5 243-02
1 pk/5 243-01
3 pk/5 243-03
Replacement Septa pk/10 233-01-RS
†  1/8–inch tolerance
* Maximum operating temperature is 225 F (107.2 C) based on fitting O-rings.

Single Stainless Steel or PTFE Fitted Bag Operating Instructions (PDF)

SKC Custom Sample Bag Order Form (PDF)

Sample Bag Brochure (PDF)

Bag Stability Report (PDF)

Bag Accessories


SKC Low Flow Pump 222 Series
SKC 222 Series low flow personal sample pumps with NiCad battery. Flow range: 50 to 200 ml/min

SKC Grab Air Bag Sampling Pump
Designed to fill sample bags at 1 L/min. Collects approximately 1000 liters volume on one battery. Recommended for use with sample bags up to 10-liter size.
Vac-U-Chamber The SKC Vac-U-Chamber ™
The SKC Vac-U-Chamber is a rigid air sample box allowing the direct filling of an air sample bag using negative pressure provided by most personal air sampling pumps.
Vac-U- Tube The SKC Vac-U-Tube ™
An easy way to take quick bag samples, the SKC Vac-U-Tube is an acrylic syringe with a removable face plate that allows a specially designed 0.7-liter SamplePro PVDF (Cat. No. 247-945A) or FlexFilm (Cat. No. 236-945A) bag to be placed inside.
Tubing PTFE Tubing
Use only PTFE tubing for bag sampling to prevent loss through adsorption to the tubing surface.