SKC: Shaping the Future of Air Sampling  

 

 

UMEx 400
Passive Sampler for Amines

Easy, Economical, and Reliable Collection of Amines

 

  • Accurate and reliable

  • Economical and easy to use
    • No pump or training required
    • Low-cost single-use sampler
    • Sample medium and blank correction in one unit

  • Highly sensitive and specific analysis method

  • Small and unobtrusive

  • Simple-to-use "on/off" sliding cover

  • Safe
    • No glass or chemical liquids in the sampler

  • Concentration range from 0.5 to 10 ppm

  • Personal or area sampling


UMEx Spec. Sheet (PDF)

UMEx Operating Instructions (PDF)

Research Report: Determination of Aliphatic Amines Using the SKC UMEx 400 Diffusive Sampler (PDF)


The single-use UMEx 400 Passive Sampler for Amines was developed in collaboration with the National Institute of Working Life in Umea, Sweden. Constructed of tough polypropylene, the UMEx 400 contains a tape treated with 1-Naphthyl-isothiocyanate (NITC) for reliable collection of amines. Samplers are provided in individual aluminized pouches that can be reused to transport the sampler to a laboratory after sampling. For convenience and quality control assurance against contamination, each sampler incorporates a "blank correction" section in addition to the active sampling section so there is no need to send extra samplers to the laboratory. The shelf-life date is printed on a label on the outside of each pouch for easy inventory management. The UMEx 400 Sampler includes a clip for attachment to a worker's collar for personal sampling or in an appropriate location for area sampling.

 

500-400 UME<SUP>x</SUP> Pssive sampler for Amines Sampler closed with callouts
500-400 UME<SUP>x</SUP> Pssive sampler for Amines Sampler open with callouts
UMEx Sampler with
sliding cover in "off" position
UMEx Sampler with
sliding cover in "on" position

Using the Passive Sampler

Sampling with the UMEx 400 Sampler is very easy and requires no pump or training. Simply remove the badge from the pouch, record sampling information on the back of the sampler, and slide the cover to the "on" position. Clip the sampler on a worker for personal sampling or in an appropriate location for area sampling for up to 8 hours. When sampling is complete, simply slide the cover to the "off" position, place the sampler back in the pouch, and seal. Send the sampler to an accredited laboratory for analysis by high-performance liquid chromatography with UV detection (HPLC-UV).

Performance Profile
Concentration Range
0.5 to 10 ppm
Detection Principle
Formation of a stable amine derivative, made from a reaction of the amine with the NITC
Analysis Method
Analysis by HPLC with UV detection at 254 nm
Accuracy
± 25% for all amines except methyl amine
± 35% for methyl amine
Shelf-life
12 months from date of manufacture in freezer
Storage

Before use: < 39.2 F (4 C)

After use: Samples can store at ambient temperatures for 14 days

For storage greater than 14 days, store at < 39.2 F (4 C).

Caution: Do not store with food.

Temperature Effects
No effect on sampling rate from 50 to 86 F (10 to 30 C)
Humidity Effects
No effect on sampling rate from 10 to 80% relative humidity (RH)
Wind Velocity Effects
No effect from 5 to 100 cm/sec
Interferences
None found; highly specific for amines
Validation
Partial
Dimensions
3.4 x 1.1 x 0.35 in (8.6 x 2.8 x 0.89 cm)
Weight
0.38 oz (10.9 grams)
Slide Cover
Blue

Sampling Rates
Compound Sampling Rate
(ml/min)
RSD
Methyl amine 18.4 14.0
Dimethyl amine 18.2 5.8
Isopropyl amine 13.9 9.5
Allyl amine 22.4 7.7
n-Butyl amine 18.1 9.2

Ordering Information    

Description Qty. Cat. No.
UMEx 400 Passive Sampler for Amines
UMEx samplers are designed for single use only. Do Not reuse UMEX samplers.
Limited shelf-life; storage < 39.2 F (4 C) required. Do not store with food.

10

500-400


UMEx Spec. Sheet (PDF)

UMEx Operating Instructions (PDF)

Research Report: Determination of Aliphatic Amines Using the SKC UMEx 400 Diffusive Sampler (PDF)

List of Laboratories for Analyzing 400-Series UMEx Passive Samplers

References

Lindahl, R., Levin, J.O., and Andersson, K., "Determination of Volatile Amines in Air by Diffusive Sampling, Thiourea Formation and High-Performance Liquid Chromatography," Journal of Chromatography, 643, 1993, pp. 34-41.

Note: UMEx was developed in collaboration with:
Jan O. Levin
Arbetslivsinstitutet
National Institute for Working Life
Programme for Chemical Exposure Assessment
Box 7654, SE 907 13
Umea, Sweden

This page was last modified April 19, 2009
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified July 28, 2010

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc