SKC Inc. The World Leader in Sampling Technologies
English
Espanol
Deutsch
Francais
Portugues
systransoft.com
  Headlines:
          New! SKC Webinars/Podcast
    
Deal of the Month.  Special pricing Click Here

The AirChek 2000
Air Sampling Pump

PC Programmable with Flows to 3250 ml/min

AirChek 2000 Air Sampling Pump Cat. No. 210-2000
CE mark

Li-ion models

Airchek 2000 Downloads

Schedule it on a PC!
Combine AirChek 2000, your PC, and DataTrac 2000 Software to easily create single or multiple sampling schedules that include delayed start, timed shutdown, and sequential sampling. Alternatively , a single schedule can be set manually using the pump’s large integral keypad.

Sample and record it!
Start sampling with the click of a mouse or the press of a button. A patented (U.S. Patent No. 5,892,160) internal flow sensor acts as a secondary standard to accurately maintain set flow. AirChek 2000 records flow rate, run time, sample volume, and flow fault throughout the sampling period. View values on a PC in pump history or during sampling on the pump LCD.

Download and report it!
Use your PC and DataTrac 2000 Software to download pump history, import data into your favorite software for IH lab reporting, or create a worker exposure profile for complete reporting.

CalChek it!

The CalChek feature provides direct communication between an AirChek 2000 pump and a Defender primary standard calibrator. This results in highly accurate single-point calibration for pre and post-sampling and complete multiple-point calibration following pump maintenance.

Partner the AirChek 2000 pump and CalChek with your PC and DataTrac 2000 Software for documented results of calibration for ISO 9000, Total Quality Management programs, and occupational health and safety management systems.

Patented* isothermal flow control system
Accurate internal flow sensor measures flow directly and acts as a secondary standard to maintain set flow with an accuracy of ± 5%. Thermal and pressure sensors maintain flow calibration by compensating for differences between the temperature and atmospheric pressure at calibration and those during sampling.
* US Patent No. 5,892,160

Longer run times
With NiMH battery pack, run time is 12+ hours at 2000 ml/min and up to 30 inches water back pressure; dependent on sample media used

Battery status display
Indicates battery power available to operate pump

Wide flow range — 5 to 3250 ml/min
AirChek 2000 is the best choice for many sampling applications.

Low flow capability
With the easy-to-use low flow adapter kit, achieve flows from 5 to 500 ml/min (low flow does not include some electronic readout options).

Easy PC programmability
Combine AirChek 2000 and a PC with DataTrac 2000 Software to easily create multiple sampling schedules that include delayed start, timed shutdown, and sequential sampling or download sampling data to a PC for storage and analysis.

Compact, lightweight, and ultra-quiet
For greater worker acceptance

Intrinsic safety
Versatile for all industries and safe in explosive environments; UL and cUL Listed

Continuous sample volume calculations
Flow-rate, run time, volume, and flow fault are continuously recorded for accurate sample reporting.

RFI/EMI-shielded, impact-resistant case
Ensures accurate air volumes and data validity; covers protect battery charging jack and computer interface port; CE marked

Security system protects data
A security code minimizes accidental changes and maintains sample validity.

Multiple-tube sampling feature
Save valuable time with simultaneous 2, 3, or 4-tube sampling

Protective features
Auto shut-off at low battery; automatic flow fault shutdown and restart

CalChek Direct Communication to a Primary Flow Standard

212-2000 Airchek 2000 with DEFENDER Calibrator

Advanced Automatic Calibration Feature!
Direct Communication to a Primary Standard
The patented (U.S. Patent Nos. 6,227,031 and 6,363,769) CalChek automatic calibration feature makes it easy to calibrate an AirChek 2000 pump to the desired flow rate using a Defender calibrator without manual adjustments (requires an AirChek 2000 pump [version 2.59 or higher], a Defender calibrator, and CalChek communication cable). Optional DataTrac 2000 Software (version 3.62 or higher) can be used to expand the documentation capabilities of this system. CalChek allows automatic field calibration, reduces the need for frequent factory calibration, and provides two calibration options. Both types of calibration bring flow to within 5%.
  • Single-point Calibration allows setting and verifying a flow rate at a single point before and after sampling.

  • Multiple-point (Full) Calibration corrects flow to a primary standard at multiple flow rates to cover the basic operational flow range of the pump.


Fast, simple, and accurate calibration
No timers, soap film, or delicate equipment needed. The tough Defender calibrator with built in DryCal technology provides an automatic, accurate flow rate average that you can count on.

No manual adjustments
The CalChek feature provides direct communication between the AirChek 2000 Sample Pump and the Defender calibrator. No user intervention is needed. Simply set up the calibration train and push a button to start automatic calibration.

CalChek — two calibration options
With CalChek, quickly calibrate flow at a single point before and verify flow after sampling or calibrate the pump across a range of flows following repair and maintenance to ensure optimum pump performance.

Complete documentation of calibration for ISO 9000, TQM programs, and OHS management systems
CalChek, used with DataTrac Software, allows the user to download data to a PC and generate printed reports for complete documentation.

 

AirChek 2000
Easy PC Programmability
AirChek2000 Easy PC Programmability

The SKC AirChek 2000 pump, Windows-based DataTrac 2000 Software, and your PC are an unbeatable combination for creating multiple sampling schedules that include delayed start, timed shutdown, and sequential sampling and a complete documentation of sampling history.

AirChek2000 Easy PC Programmability

With DataTrac 2000:

  • Create a sample and analysis sheet for all critical information.

  • Program a complete running sequence, delayed start, timed shutdown, or intermittent sampling even at different flow rates.

  • Program single or multiple sampling schedules.

  • Save an AirChek 2000 program.

  • Access complete documentation of calibration when used with CalChek feature.

  • Download sampling data to a PC and import into word processing software to create a complete report.

  • With CalChek, download calibration data for complete documentation for ISO, TQM programs, or occupational health and safety management systems.

  • To learn more about the DataTrac software, click here to go to the DataTrac page.

AirChek 2000
Easy Operation and Long Run Times
Large easy-to-read LCD
Large easy-to-read LCD of the AirChek 2000
Continuously updated sampling data displays on the AirChek 2000 large LCD. With the press of a single button, scroll through flow rate, air volume, run time, temperature, atmospheric pressure, battery status, time of day, and flow fault. A battery status icon constantly displays and a flow fault icon flashes during restricted or blocked flow. A flashing LED on top of the pump indicates the pump is running in low-light or loud environments.

Easy Manual Programming
It’s right on the front of the pump. Set flow rate and run time without screwdrivers; simply use the 3-button keypad. A convenient timed shutdown feature allows you to program the AirChek 2000 to run for a set time from 1 to 999 minutes, a very useful feature for STELs or repetitive sample runs.
AirChek 2000 Simple 3-button Keypad
Simple 3-button Keypad

Flow Fault Features:

  • Auto shut-off with low battery or excessive back pressure

  • Adjustable flow fault shutdown from 5 seconds to 4 minutes when used with a PC and DataTrac 2000 Software

  • Auto-restart from flow fault attempted every 5 minutes for a maximum of 10 times (can be changed with DataTrac 2000 Software)

  • Run time data stored in memory

AirChek 2000 Run Time in Hours with NiMH Battery
Following are typical run times achieved when using a fully charged nickel-metal hydride (NiMH) battery pack. Data is sorted by type of sample media. All run times are listed in hours. Results are obtained using a new pump and new fully charged battery. Pump performance may vary.

  Mixed Cellulose Ester (MCE) filter, 0.8-µm pore size

Flow Rate (L/min)
Filter Diameter
37 mm
25 mm
2.0
37
32
2.5
33
26
3.0
30
21

   Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
Flow Rate (L/min)
Filter Diameter
37 mm
25 mm
2.0
44
40
2.5
36
34
3.0
31
27

Increases in back pressure during sampling due to buildup of sample on the filter can decrease battery life.


AirChek 2000 Run Time in Hours with NiCad Battery
AirChek 2000 provides long run times for sampling flexibility. Tests* show the following run times at 2 L/min. All run times are listed in hours.

  Mixed Cellulose Ester (MCE) filter, 0.8-µm pore size

Flow Rate (L/min)
Filter Diameter
37 mm
25 mm
2.0
24.2
15.2
2.5
20.4
12.4
3.0
17.7
**

   Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
Flow Rate (L/min)
Filter Diameter
37 mm
25 mm
2.0
28.2
21.8
2.5
27.0
22.0
3.0
22.6
18.2
* Results obtained using a new pump and new fully charged battery. Pump performance may vary.
** Filter back pressure exceeded pump capability during testing.

 

Performance Profile
AirChek 2000
Flow Range
1000 to 3250 ml/min
(5 to 500 ml/min requires optional low flow adapter kit)
Compensation
Range
3000 ml/min at 15 inches water back pressure
2000 ml/min at 30 inches water back pressure
1000 ml/min at 30 inches water back pressure
Flow fault
If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault mode. During flow fault, the pump enters Hold, the fault icon appears on the display during the length of the fault, and the accumulated run time display is frozen and retained. After 5 minutes in flow fault, auto-restart is attempted every 5 minutes up to 10 times.
Run Time
With NiMH battery pack, run time is 12+ hours for 2000 ml/min and up to 30 inches water back pressure; dependent on sample media used. See Table 1.
With Battery eliminator, run time is extended.
Charging Time
(varies with battery capacity and level of discharge)
6 to 8.5 hrs with PowerFlex charger
Flow accuracy
± 5% of set-point after calibration to desired flow
Atmospheric Pressure Accuracy
± 0.3 in Hg
Timing Accuracy
1 min/mo at 25 C
Operating
Temperature Range        
32 to 113 F (0 to 45 C)
Charging
Temperature Range   
50 to 113 F (10 to 45 C)
Storage
Temperature Range   
-4 to 113 F (-20 to 45 C)
Altitude Range
Do not use pump beyond 7500 ft
Battery Pack
Removable chargeable 4-cell NiMH battery, 4.8 V x 3.5-Ah capacity
Size
5.6 x 3 x 2.3 in
(14.2 x 7.6 x 5.8 cm)
Weight
22 oz
(624 gm)
Intrinsic Safety
UL and cUL Listed
Case
Impact resistant
RFI/EMI shielded
CE marked

Protect sample pump from weather when in use outdoors.



Table 1: Typical Back Pressure of Sampling Media (inches water)

Filter/Pore Size (µm) Flow Rate (L/min)
1.0 1.5 2.0 2.5 3.0
25-mm MCE, 0.8 6 9 12 15 18
25-mm MCE, 0.45 14 22 28 35 40
37-mm MCE, 0.8 2 3 4 5 6
37-mm PVC, 5.0 1 1 2 2 2.5

Compare the information in this table to pump compensation range to determine appropriate applications.

 

Ordering Information      

Pumps
Voltage
Cat. No.
AirChek 2000 Pump with NiMH battery pack and screwdriver set, requires charger, see kits or chargers below
AirChek 2000 Pump without Battery
Single AirChek 2000 Kit (High Flow) includes AirChek 2000 pump, single PowerFlex charger with cable, filter cassette holder, and soft-side nylon carry case
100-240 V
AirChek 2000 High Flow Single Pump Kit with Hard-side Pelican Case includes pump, single charger with cable, filter cassette holder, and hard-side Pelican case
100-240 V
AirChek 2000 Starter Kit includes pump with battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie
100-240 V
5-pack AirChek 2000 Kit (High Flow) includes 5 AirChek 2000 pumps and filter cassette holders and one 5-station PowerFlex charger with 5 cables, in a Pelican case
100-240 V
5-pack AirChek 2000 Kit (High and Low Flow) includes 5-pack high flow items, 5 adjustable low flow holders, 5 constant pressure controllers, and 5 Type A tube covers
100-240 V
5-pack AirChek 2000 High Flow CalChek Kit includes 5 pumps with NiMH batteries, 5-station PowerFlex Charger with 5 cables, 5 filter cassette holders, a CalChek communication cable, Defender calibrator with charger, and a Pelican carry case
100-240 V
Pump Certificate
Certificate of Compliance, optional, must be ordered when ordering pump
Software
DataTrac 2000 Software Package includes software on CD, DataTrac adapter, and DataTrac cable, Requires Windows 98 or higher and available serial port or USB to 9-pin serial adapter that is compatible with the PC and system
Download DataTrac 2000 now
Calibrators and Accessories
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes lead-acid battery, charger, Optimizer software, and 39-inch (1-meter) serial cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and an RS-232 port or USB to RS-232 adapter
Defender Primary Standard Calibrator
Defender Primary Standard Calibrator, 50 to 5000 ml/min, includes lead-acid battery, multi-plug charger (100-240 V), Optimizer software, and 39-inch (1-meter) serial cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and an RS-232 port or USB to RS-232 adapter.
Defender Primary Standard Calibrator
Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs
Defender Universal Charger, 100-240 V, with U.S. plug
CalChek Communication Cable, provides direct communication between a CalChek-compatible AirChek 2000 or Leland Legacy pump and a CalChek-capable Defender primary standard calibrator
Note: For use only with Defender calibrators with Revision Level C or higher
Required for CalChek calibration, included in CalChek kit above
Chargers — PowerFlex Charging Systems
PowerFlex 5-station 100-240 V includes power supply and cord
Purchase pump-specific cables separately; choose from the list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved models
223-1000
PowerFlex Single 100-240 V includes power supply and cord
Purchase pump-specific cables separately; choose from the list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved models
223-2000
Replacement CE-marked Power Supply for 5-station PowerFlex Charger P22310
PowerFlex Cables
PowerFlex Cable for AirChek 2000, 1 cable
223-1001 Cables
Batteries and Battery Eliminators
Replacement AirChek 2000 NiMH Battery Pack
Replacing batteries with non-approved battery packs voids the pump warranty and UL listing for intrinsic safety.
Replacement AirChek 2000 NiCAD Battery Pack
Replacing batteries with non-approved battery packs voids the pump warranty and UL listing for intrinsic safety.
AC Adapter (Battery Eliminator) 115 V, connects pump to line power for extended pump operation
Battery Eliminator should be used in non-hazardous locations only.
223-320
AC Adapter (Battery Eliminator) 230 V, connects pump to line power for extended pump operation
Battery Eliminator should be used in non-hazardous locations only.
223-320B
Pouches and Carry Cases
Protective Nylon Pump Pouch, Black with belt and adjustable waist and shoulder strap designed for worker comfort when using an AirChek 2000 or 52 pump  
Protective Nylon Pump Pouch, High-profile red for with belt and adjustable waist and shoulder strap designed for worker comfort when using an AirChek 2000 or 52 pump
Protective Nylon Pump Pouch, Black Nylon, Noise-reducing, with belt and adjustable waist and shoulder strap designed for worker comfort when using an AirChek 2000 or 52 pump
Kit Case
Single Deluxe Case (Pelican), for SKC pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof; will accommodate a single pump and accessories
Kit Cases Single Deluxe Case (Pelican) Cat. No. 224-901
5-Pack Pump Carry Case, Pelican, for AirChek XR5000, AirChek 2000, AirChek 52, and AirLite pumps. On wheels for easy transport, watertight, airtight, dustproof, and crushproof, equipped with foam for complete equipment protection
Sampling Accessories
AirChek 2000 Low Flow (5 to 500 ml/min) Adapter Kit includes constant pressure controller (CPC), single adjustable low flow holder, and Type A tube cover AirChek 2000 Low Flow (5 to 500 ml/min) Adapter Ki
Replacement Parts and Tools
Replacement Filter/O-ring, includes 3 filters and O-rings
Replacement Inlet/Filter Housing
SKC Pneumatic Test Kit, for testing flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to 80 inches magnehelic pressure gauge 224-6580 SKC Pneumatic Test Kit
SKC Universal Screwdriver Kit, for use with sample pumps, includes 3 interchangeable screwdriver heads 224-11
Mini Tool Kit, for use with air sampling pumps and filter media, includes scissors, pliers, file, 2 slotted screwdrivers, 2 Phillips screwdrivers, forceps, and charcoal pick Mini Tool Kit  376-01-01 376-01-01

AirChek 2000 Spec. Sheet (PDF)

AirChek 2000 Operating Instructions (PDF)

AirChek 2000 Quick Guide (PDF)

CalChek with the Defender Operating Instructions (PDF)

Battery Pack for AirChek 2000 Operating Instructions (PDF)

MSDS for Nickel Cadmium Battery GPI International (PDF)

MSDS for Nickel Cadmium Battery SANYO Energy (PDF)

MSDS for Nickel-metal Hydride Battery (PDF)

Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)

DataTrac 2000 Software Package

AirChek 2000 210-2002 UL Certificate

AirChek 2000 210-2002 UL Certified for Canada Certificate

EMC Test Certificate (PDF)

CE Conformity Declaration (PDF)

KEMA (Keuring van Electrotechnische Materialen) Certificate of Conformity (PDF)

Instrucciones de Operación (PDF)

Bedienungsanleitung (Kurzfassung)(PDF)

Téléchargement Guide de I'utilisateur (PDF)

Chinese Language AirChek 2000 Operating Instructions (PDF)

AirChek 2000 FAQs


SKC Air Sampling Pumps

Pump Accessories (Chargers, Calibrators, Flowmeters)


This page was last modified November 15, 2011
  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified February 6, 2012
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2012 SKC Inc