Universal Pumps
44XR
1000 to 5000 ml/min
(5 to 500 ml/min Low Flow Applications)
Reliable Air Sampling
Economical and Easy to Use
Personal or Area Sampling
|
|
|
ATEX-approved
models available
|

MSHA-approved
models available
|
Ordering Information
44XR
Operating Instructions (PDF)
44XR
Spec. Sheet (PDF)
Technical
Note: SKC Sample Pump Battery Pack Characteristics and Maintenance
(PDF)
Battery
Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
UL
Certificate of Intrinsic Safety (PDF)
EC
Declaration of Conformity (PDF)
MSHA
Approval Certificate (PDF)
Instrucciones
de Operación 224-44XR (PDF)
Bedienungsanleitung
224-44XR (PDF)
Mode
d’emploi Pompe de prélèvement universelle 224-44XR
(PDF)
Performance Profile
224-44XR Air Sampling Pump
| Operating Range |
1000 to 5000 ml/min (UL Listed
model)
1000 to 3000 ml/min (MSHA-approved model)
(5 to 500 ml/min requires the 224-26 Series Adjustable
Low Flow Holder)
|
| Weight |
34 oz (964 gm) |
| Dimensions |
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm) |
| Compensation Range |
1000 to 2500 ml/min at 40 inches water back pressure
3000 ml/min at 35 inches water back pressure
4000 ml/min at 20 inches water back pressure
5000 ml/min at 10 inches water back pressure |
Typical Back Pressure |
See Table 1. |
|
Flow Control
|
Holds constant flow to ± 5%
of set-point |
| Run Time |
NiCad Battery: 8 hours minimum at 4000
ml/min and 20 inches water back pressure; dependent on
media used. See
Table 3.
NiMH Battery: 12 hours minimum at 4000
ml/min and 20 inches water back pressure; dependent on
media used. See
Table 2.
Battery Eliminator: Pump provides extended
runs. |
|
Flow Indicator
|
Built-in rotameter with 250-ml division; scale
marked at 1, 2, 3, 4, and 5 L/min |
| Power Supply |
6.0-V plug-in NiMH battery pack, rechargeable,
3.5-Ah capacity or 6.0-V plug-in NiCAD battery pack, rechargeable,
2.0-Ah capacity
A battery eliminator is available (see Ordering Information);
use voids the UL Listing for intrinsic safety. |
| Intrinsic
Safety |
UL Listed for Class I, Division 1 and 2, Groups
A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and
Class III, Temperature Code T3C
ATEX-approved models are available. Contact
SKC. |
| Operating Temperature |
32 to 113 F (0 to 45 C) |
| Storage Temperature |
-4 to 113 F (-20 to 45 C) |
| Charging Temperature |
50 to 113 F (10 to 45 C) |
| Operating Humidity |
0 to 95% non-condensing |
|
Multiple-tube Sampling
|
Built-in constant pressure regulator allows user
to take up to four simultaneous samples with rates up to 500
ml/min each (total combined flow 1350 ml/min maximum) using
the optional adjustable low flow holder accessory |
| RFI/EMI Shielding |
Complies with requirements of EN 55022, FCC Part
15 Class B, EN 50082-1
Frequency range of the radiated susceptibility test was 27 to 1000 MHz
CE marked |
| Additional Specifications |
Built-in fluid/particulate trap
External see-through filter housing
Tamper-resistant control cover
Tamper-resistant compensation adjustments
Built-in accessory mount
Stainless steel belt clip
External exhaust port
All non-plastic parts made of corrosion-resistant materials
RFI and EMI-shielded case
|
| Additional Features |
One-year warranty
Ultra-quiet operation
Pulsation-free flow
Impact-resistant case
|
Protect sample pump from weather when in use outdoors.
Universal Samplers FAQs
Ordering Information
Table 1.
Typical Back Pressure of Sampling Media (inches water)
Compare the information in this back pressure table to pump
compensation
range
to determine appropriate applications.
| Filter/Pore Size
(µm) |
Flow
Rate (L/min) |
| 1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
| 25-mm MCE/0.8 |
6 |
9 |
12 |
15 |
18 |
| 25-mm MCE/0.45 |
14 |
22 |
28 |
35 |
40 |
| 37-mm MCE/0.8 |
2 |
3 |
4 |
5 |
6 |
| 37-mm PVC/5.0 |
1 |
1 |
2 |
2 |
2.5 |
Table 2.
Pump Run Time in Hours with NiMH Battery
Following are typical run times achieved when using a fully
charged nickel-metal hydride (NiMH) battery pack. Data is sorted by
type of sample media. All run times are listed in hours. Results are
obtained using a new fully charged battery. Pump performance may vary.
Mixed Cellulose (MCE) filter, 0.8-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
37 |
33 |
| 2.5 |
34 |
26 |
| 3.0 |
31 |
21 |
| 3.5 |
29 |
18 |
| 4.0 |
25 |
15 |
| 4.5 |
20 |
14 |
Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
47 |
41 |
| 2.5 |
38 |
33 |
| 3.0 |
35 |
30 |
| 3.5 |
26 |
27 |
| 4.0 |
22 |
25 |
| 4.5 |
21 |
23 |
| NOTE: |
Increases in back pressure during sampling due
to buildup of sample on the filter can decrease battery life. |
Table 3.
Pump Run Time in Hours with NiCad Battery
Following are typical run times achieved when using
a fully charged nickel cadmium (NiCad) battery pack. Data is
sorted
by type of sample media. All run times are listed in hours.
Results are obtained using a new fully charged battery. Pump
performance may
vary.
Mixed Cellulose (MCE) filter, 0.8-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
24.1 |
16.3 |
| 2.5 |
21.4 |
14.5 |
| 3.0 |
19.1 |
11.0 |
| 3.5 |
17.8 |
10.7 |
| 4.0 |
15.4 |
** |
| 4.5 |
14.6 |
** |
**
|
Filter back pressure exceeded pump
capability during testing. |
Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
31.6 |
21.7 |
| 2.5 |
27.7 |
24.0 |
| 3.0 |
27.0 |
18.6 |
| 3.5 |
22.8 |
16.4 |
| 4.0 |
19.4 |
16.2 |
| 4.5 |
19.0 |
14.6 |
| NOTE: |
Increases in back pressure during sampling due to buildup
of sample on the filter can decrease battery life. |
Simple to Operate
With its broad flow range, the powerful 44XR air
sampling pump does the work of both a high flow and a low flow pump
in a single pump unit. Designed for rugged environments and repeated
use,
its state-of-the-art pneumatic system delivers a constant flow,
so users can get accurate air volumes without the need for frequent
sampler adjustments. This system includes:
- Pulsation dampener for smooth airflow
- Built-in flowmeter to monitor pump flow
- Pressure regulator for low flow sampling
- Filter assembly to prevent clogging of the pump
All SKC XR Series Universal Air Sampling Pumps are equipped with a stainless
steel belt clip, built-in accessory mount for impinger brackets, anti-tamper
control cover, and external exhaust port for bag sampling applications. For easy
repair, replacement parts are available in preassembled modules.
Personal or Area Sampling
The result of extensive research and development, the PCXR4 is a constant flow
air sampling pump suited for a broad range of applications. With an operating
range of 1000 to 5000 ml/min (low flow applications of 5 to 500 ml/min require
an optional adjustable low flow holder), this battery-operated air sampling pump
is ideal for industrial hygiene studies as well as environmental testing. Specifically
designed for on-worker and fenceline applications, the PCXR4
air sampling pump is typically used with collecting devices such as:
- Sorbent sample tubes and
Long-duration detector tubes for collecting most hazardous chemical gases and vapors
from the air
- Cyclones for collecting respirable dust
- IOM samplers for collecting inhalable
dust
- Filters for collecting total dust, asbestos,
or chemical hazards
- Tedlar sample bags for collecting airborne chemical
hazards
- Impingers for collecting reactive chemicals
into liquids
The 44XR air sampling pump is so dependable, we guarantee its performance for
a period of one year from date of purchase.
Ordering Information
Back Pressure Compensation
The 44XR is factory-preset to compensate for back pressures
to 40 inches water over the most commonly used flow ranges. As back pressure
increases, the motor voltage automatically corrects to maintain a constant
flow over
the operating range. There is no sacrifice to air volume accuracy, even in dusty
environments.
Lightweight and Durable
Weighing only 34 ounces, the 44XR is suited ideally
to personal sampling. A tamper-resistant cover and durable construction allow
the
pump to
withstand
the rigors of on-worker use time and time again. Rechargeable batteries
provide a reliable power source that can be restored overnight. The 44XR is a
workhorse air sampling pump, designed for rugged, repeated use.
RFI and EMI Shielding
44XR case material and unique circuitry are designed to provide shielding from
radio frequency in the range of 27 to 1000 MHz. This shielding prevents fluctuations
in the flow caused by electrical effects on the pump's control circuitry. CE
marked.
A High Standard of Safety
Intrinsically safe, the 44XR is UL Listed for explosive gas
and dust atmospheres of Class I, Division 1 and 2, Groups A, B, C, D; Class II,
Division 1 and 2, Groups E, F, G;
and Class III, Temperature Code T3C.
ATEX-approved
model is available. Contact
SKC.
The Indispensable Air Sampling Pump
Highly accurate yet easy to operate, the versatile 44XR is
suited for industrial hygiene studies as well as environmental testing. Specifically
designed for on-worker or personal applications, this sampler is typically
used for TWA, STEL, or Ceiling sampling using a wide range of sampling media
including:
Ordering Information
Multiple-tube Sampling Capability
The 44XR built-in constant pressure regulator allows users
to take up to four simultaneous samples with rates up to 500 ml/min each
using an optional adjustable low flow holder (not included). Reduce time
in the field and use fewer pumps with multiple-tube
air sampling.
Long-life NiMH Battery Pack
The NiMH battery pack provides a minimum 12-hour continuous run time. The
battery charge test ensures the pump runs the entire shift.
A Variety of Ordering Options
The 44XR and its accessories can be purchased together in
single and five-pack pump kits or separately for a more customized setup. Accessories
include chargers (single or five station), adjustable low flow holders, filter
cassette holders, impinger holders, and a protective nylon carrying pouch with
shoulder strap and belt.
Note: Kits do not contain all the accessories
listed here. Contact your
SKC regional sales representative for
complete ordering information.
Ordering Information
| Description |
Cat. No.
|
44XR Air Sampling Pump Only (without charger) includes
constant flow air sampling pump with RFI/EMI-shielded case and battery
pack, screwdriver set, and instruction manual
Requires charger; see kits or accessories below
ATEX-approved models are available. Contact
SKC. |
|
|
| 44XR Single Pump Kit, High/Low Flow, includes
sample pump with NiMH battery pack, single PowerFlex charger with cable,
adjustable low flow holder, Type A tube cover, filter cassette
holder, and screwdriver set, in a convenient soft-side nylon carry case |
100-240 V
|
|
| 44XR Single Pump Kit, High/Low
Flow with Hard-side Pelican Case, includes pump with NiMH
battery pack, single PowerFlex charger with cables, low flow holder,
Type A
tube cover, filter cassette holder and screwdriver
set, in a hard-side Pelican case |
100-240 V
|
|
| 44XR Starter Kit includes pump with battery, charger,
Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie |
100-240 V |
224-44XR-S |
| 44XR 5-pack Pump Kit, High/Low Flow, includes 5 sample
pumps with NiMH battery packs, adjustable low flow holders, Type A
tube covers, filter cassette holders, and screwdriver sets and one 5-station
PowerFlex charger with cables, in a Pelican carry case |
100-240 V
|
|
MSHA-approved 44XR Air Sampling Pump Only (without charger) includes
NiCad battery pack battery pack; flow range 5 to 3000 ml/min
Requires charger; see kits or accessories below |
|
|
| MSHA-approved 44XR Single Pump Kit, High/Low Flow, includes
sample pump with NiCad battery pack, single charger with cable, adjustable
low flow holder, Type A protective tube cover, filter cassette holder,
screwdriver set, in a carry case |
100-240 V |
224-44XRKM |
| MSHA-approved 44XR 5-pack Pump Kit, High/Low Flow, includes
5 sample pumps with NiCad battery packs, adjustable low flow holders, Type
A tube covers, filter cassette holders and screwdriver sets,
and one 5-station charger, in a carry case |
100-240 V |
224-44XRK5M |
| Pump Certificate |
Cat. No.
|
| Certificate of Compliance, optional, must
be ordered when ordering pump |
|
| Calibrators |
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes
lead-acid battery, charger, Optimizer software, and 39-inch (1-meter)
serial cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit
version) and an RS-232 port or USB to RS-232 adapter.
|
 |
|
Defender Primary Standard Calibrator, 50 to 5000
ml/min, includes lead-acid battery, multi-plug charger (100-240
V), Optimizer software, and and 39-inch (1-meter) serial cable
Software
requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and
an RS-232 port or USB to RS-232 adapter. |
 |
|
| Replacement Defender Lead-acid Battery Pack |
|
| Defender Universal Charger, 100-240 V,
with U.S., Euro, and Australia plugs |
|
| Defender Universal Charger, 100-240 V,
with U.S. plug |
|
| Chargers — PowerFlex Charging
Systems |
Cat. No.
|
PowerFlex 5-station 100-240 V includes
power supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-1000 |
PowerFlex Single 100-240 V includes power
supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-2000 |
| Replacement CE-marked Power Supply for
5-station PowerFlex Charger |
P22310 |
|
PowerFlex Cables
|
Cat. No.
|
| Universal XR Series (5-cell), 1 cable |
|
|
| Universal XR Series (4-cell, MSHA), 1 cable |
|
|
| Replacement Battery Packs |
Cat. No. |
|
Replacement Battery Pack, NiMH, for
XR models
Not suitable for MSHA-approved models
Replacing batteries with non-approved battery packs voids the pump
warranty and UL listing for intrinsic safety.
|
|
|
Replacement Battery Pack, NiCad
Not suitable for MSHA-approved models
Replacing batteries with non-approved battery packs voids the pump
warranty and UL listing for intrinsic safety.
|
|
|
Replacement Battery Pack, NiCad, for MSHA-approved
models
Replacing batteries with non-approved battery packs voids the
pump warranty and UL listing for intrinsic safety.
|
|
AC Adapter (Battery Eliminator) 115 V, for
extended run times
Use of the Battery Eliminator voids the UL Listing for intrinsic
safety.
|
|
AC Adapter (Battery Eliminator) 230 V, for
extended run times
Use of the Battery Eliminator voids the UL Listing for intrinsic
safety. |
|
| Pump Carry Cases |
Cat. No. |
Protective Nylon Pump Pouch with belt and adjustable
waist and shoulder strap designed for worker comfort when using Universal
XR samplers
High-profile Red, for easy observation |
 |
|
Protective Nylon Pump Pouch with belt and adjustable
waist and shoulder strap designed for worker comfort when using Universal
XR samplers
Black
|
 |
|
Kit Cases
Single Deluxe Case (Pelican), single pump carry case for SKC
pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof;
will accommodate a single pump and accessories |
 |
224-901
|
| 5-pack Kit Carry Case (Pelican), Universal
XR series, watertight, airtight, dust proof, and crush proof, equipped
with foam for complete equipment protection |
|
| Replacement Parts and Tools |
Cat. No. |
| Pump Service Training Set for Universal XR Series
Pumps includes a manual and video for distributors and customers
who maintain and repair large numbers of Universal XR Series Pumps. The
service video on DVD
provides basic assembly/disassembly and functional testing. |
|
| Replacement Top Valve Plate, for AirChek
52 and Universal Series Pumps |
|
| Exhaust Port |
P22417C |
| Replacement Tamper-resistant Cover |
|
| Replacement External Screws, set |
|
| Replacement Cap Screw, set
of 2 |
|
| Replacement Filter Housing, air
inlet port and particulate trap |
|
Replacement Filter Kit includes
3 filters and 3 O-rings
|
|
Replacement Filters Only, pk/10
|
|
| Replacement Filter Kit, Economy, includes 100 filters
and 10 O-rings |
|
| SKC Pneumatic Test Kit, for testing
flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to
80 inches magnehelic pressure gauge |
|
| SKC Universal Screwdriver Kit, for
use with sample pumps, includes 3 interchangeable screwdriver heads |
|
| Mini Tool Kit, for use with air sampling pumps and
filter media, includes scissors, pliers, file, 2 slotted screwdrivers,
2 Phillips screwdrivers, forceps, and charcoal pick |
 |
376-01-01
|
44XR
Operating Instructions (PDF)
44XR
Spec. Sheet (PDF)
Technical Note:
SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
Battery
Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
UL
Certificate of Intrinsic Safety (PDF)
EC
Declaration of Conformity (PDF)
MSHA
Approval Certificate (PDF)
Instrucciones
de Operación 224-44XR (PDF)
Bedienungsanleitung
224-44XR (PDF)
Mode
d’emploi Pompe de prélèvement universelle 224-44XR
(PDF)
All SKC Universal Air Sampling Pumps are available with European approvals.
Contact the SKC International Sales Department at 724-941-9701 or e-mail
at skcorder@skcinc.com for ordering
information.
This page was last modified March 2, 2010